MEC19-01074
| Pressure Test | 4/4/2019 | 4/4/2019 | 4/4/2019 4:02:43 PM | P | PASS |
|
|
Inspection requested via web by william kerwin
|
MEC19-01074
| Rough-in | 4/4/2019 | 4/4/2019 | 4/4/2019 4:02:32 PM | P | PASS |
|
|
Inspection requested via web by william kerwin - R/I ok
|
MEC19-01073
| Pressure Test | 4/4/2019 | 4/4/2019 | 4/4/2019 4:02:16 PM | P | PASS |
|
|
Inspection requested via web by william kerwin - 20lb gas pressure test ok - 5lb flue pressure test ok - tagged meter location
|
MEC19-01073
| Rough-in | 4/4/2019 | 4/4/2019 | 4/4/2019 4:01:43 PM | P | PASS |
|
|
Inspection requested via web by william kerwin - R/I ok
|
MEC19-01202
| Final | 4/4/2019 | 4/4/2019 | 4/4/2019 3:43:55 PM | P | FAIL |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - line sets need support outside - existing furnace flues are being ran in single wall pipe with insulation wrapped around it. Single wall pipe needs to be removed and replace with B vent in the unconditioned attic
|
MEC19-00990
| Final | 4/2/2019 | 4/4/2019 | 4/4/2019 3:00:25 PM | P | PASS |
|
|
please call our lead installer Harley when 30-45 mins in route so he can have flue under pressure when you arrive Phone #: ###-#### Inspection requested via web by Rick Montgomery - 5lb flue pressure test ok - furnace ac coil co ok
|
MEC19-01309
| Rough-in | 4/4/2019 | 4/4/2019 | 4/4/2019 2:47:33 PM | P | PASS |
|
|
- bathroom exhaust ok - mini split is a homeowners kit all line set and condensate line will be exposed. Will check at final
|
MEC18-02774
| Final | 4/3/2019 | 4/4/2019 | 4/4/2019 2:23:20 PM | P | NH |
|
|
Inspection requested via web by Marisa Hone - no access to unit 201 left notice on front door
|
MEC19-01368
| Pressure Test | 4/4/2019 | 4/4/2019 | 4/4/2019 2:06:33 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - 20lb gas pressure test ok - tagged meter location - need to add gas piping to permit before final
|
MEC19-01359
| Final | 4/3/2019 | 4/4/2019 | 4/4/2019 1:46:57 PM | P | PASS |
|
|
Please call Craig on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace ac coil co ok
|
MEC19-00579
| Final | 4/2/2019 | 4/4/2019 | 4/4/2019 1:29:13 PM | P | PASS |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - final ok
|
MEC19-00129
| Final | 4/4/2019 | 4/4/2019 | 4/4/2019 1:25:42 PM | P | PASS |
|
|
CODEs: 5674 or WEST 9378
Riverwood (3/5 Bonneville) 7672 S. Wagons View Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace final ok
|
MEC19-01258
| Rough-in | 4/3/2019 | 4/4/2019 | 4/4/2019 11:19:54 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello - Man J needs stamped by the City of Boise
|
MEC19-01258
| Pressure Test | 4/3/2019 | 4/4/2019 | 4/4/2019 11:19:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello - 20lb gas pressure test ok -5lb flue pressure test ok - tagged meter location
|
MEC19-01174
| Rough-in | 4/3/2019 | 4/4/2019 | 4/4/2019 11:18:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - R/I ok
|
MEC19-01326
| Rough-in | 4/3/2019 | 4/4/2019 | 4/4/2019 11:18:13 AM | A | PASS |
|
|
Eaglewood (3/7 Bonneville) 7592 S. Wagons West Ave Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace R/I ok
|
MEC19-00836
| Pressure Test | 4/3/2019 | 4/4/2019 | 4/4/2019 10:34:53 AM | A | PASS |
|
|
Underground gas line pressure test. if questions call Omar @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - 60lb gas pressure test ok to last underground line
|
MEC18-03532
| Final | 4/3/2019 | 4/4/2019 | 4/4/2019 10:07:08 AM | A | NH |
|
|
Inspection requested via web by Marisa Hone - no access to home left notice on front door
|
MEC19-01074
| Rough-in | 4/3/2019 | 4/4/2019 | 4/4/2019 9:43:09 AM | A | FAIL |
|
|
Bj 2085730755 Inspection requested via web by william kerwin
- man J needs to be stamped by the city of boise - exhaust fans needs ducts sealed
- floor boots need sealed -return duct in bedroom needs sealed
- dryer vent needs nail plate
- range hood venting ??
|
MEC19-01073
| Rough-in | 4/3/2019 | 4/4/2019 | 4/4/2019 9:41:59 AM | A | FAIL |
|
|
Bj 2085730755 Inspection requested via web by william kerwin - man J needs to be stamped by the city of boise - gas test fail - return duct in bedroom needs sealed - range hood venting ??
|
MEC19-01073
| Pressure Test | 4/3/2019 | 4/4/2019 | 4/4/2019 9:40:50 AM | A | FAIL |
|
|
Bj 2085730755 Inspection requested via web by william kerwin - 20lb gas pressure test fail
|
MEC19-01074
| Pressure Test | 4/3/2019 | 4/4/2019 | 4/4/2019 9:39:11 AM | A | PASS |
|
|
Bj 2085730755 Inspection requested via web by william kerwin - 20lb gas pressure test ok - tagged meter location
|
MEC19-01331
| Final | 4/3/2019 | 4/4/2019 | 4/4/2019 8:53:10 AM | A | PASS |
|
|
Please call Lisa at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority - final ok
|
MEC18-03451
| Mec-Aging Inspection | 4/4/2019 | 4/4/2019 | 4/4/2019 8:50:35 AM | | DONE |
|
|
Called Greens heating and talked with office about their mechanical aging permit. Schedule inspection with owner if work is complete. Permit will expire in180 days if not active
|
MEC18-03456
| Mec-Aging Inspection | 4/4/2019 | 4/4/2019 | 4/4/2019 8:31:18 AM | | DONE |
|
|
Called Perfect Air and talked with Andrea about the mechanical aging permit. Schedule inspection with homeowner if work is done. Permit will expire in 180 days if not active
|
MEC18-03487
| Mec-Aging Inspection | 4/4/2019 | 4/4/2019 | 4/4/2019 8:29:53 AM | | DONE |
|
|
Called Perfect Air and talked with Andrea about the mechanical aging permit. If work is finished schedule inpsection with homeowner. Permit will expire in 180 days if not active
|
MEC18-03457
| Mec-Aging Inspection | 4/4/2019 | 4/4/2019 | 4/4/2019 8:25:00 AM | | DONE |
|
|
Called Jim's heating and talked with office about their mechanical aging permit. Schedule inspection with homeowner. Permit will expire in 180 days if not active
|