Inspections for the day of: Tuesday, April 5, 2005.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01106 Temporary Service4/4/20054/5/20054/5/2005 12:00:00 AMAPASS
Internet Inspection Request from: Bob Glenn t/s u/g n ok 4/5/2005 9:21:46 AM
ELE05-00588 Electrical Rough-In4/4/20054/5/20054/5/2005 12:00:00 AMAPASS
underground inspection please///chris; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to cover u/g to shop 4/5/2005 8:36:47 AM
ELE05-01119 Final4/4/20054/5/20054/5/2005 12:00:00 AMAPASS
We deleted the existing exposed knob/tube wiring feeding the existing weather proof GFCI receptacle under the back deck by installing a PVC j-box on the knob/tube wires as they exited the house, and installed LTNM flex and a PVC box with bubble cover for the existing GFCI receptacle.This is all outdoors for your access.Thanks!!!Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell called cont, ok to final 4/5/2005 10:32:33 AM
ELE05-00911 Permanent Service4/4/20054/5/20054/5/2005 12:00:00 AMAPASS
nolan-- cell ###-#### p/s u/g n ok 4/5/2005 9:01:08 AM
ELE05-01080 Permanent Service4/4/20054/5/20054/5/2005 12:00:00 AMAPASS
kevin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore corrections made p/s o/h n ok 4/5/2005 7:40:02 AM
ELE05-01123 Electrical Rough-In4/4/20054/5/20054/5/2005 12:00:00 AMAFAIL
###-#### - dino called contr, left corr notice,110.12(A) unused openings in panel shall be closed,110.12(C) boxes shall not be broken, 314.17(C) cable clamp shall be provided in pan boxes 4/5/2005 10:23:34 AM
ELE05-01124 Electrical Rough-In4/4/20054/5/20054/5/2005 12:00:00 AMAFAIL
###-#### - dino called contr, left corr notice, 300.4(D) cable shall be 1 1/4" from edge of framing member, 110.12(C) broken boxes shall be replaced, 314.17(C) pan box shall have clamp 4/5/2005 10:30:32 AM
ELE04-03672 Permanent Service4/4/20054/5/20054/5/2005 12:00:00 AMANR
I ALSO NEED A WALL COVER FOR THIS SAME PERMIT SOFFIT WAS INSPECTED ALREADY THANKS ; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen met with elect , ric hall, mech rm, baths ok. not ready for p/s 4/5/2005 8:25:42 AM
ELE04-02595 Final4/5/20054/5/20054/5/2005 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 4/5/2005 at 8:53:27 AM. Contact: ###-####. 2nd fl no 1/2, 3rd fl so 1/2, 1st fl 8 room so side ok to final 4/5/2005 4:13:51 PM
ELE05-01136 Rough-In Permanent Service4/5/20054/5/20054/5/2005 12:00:00 AMPFAIL
steve ###-#### called contr, left corr notice, 300.4(B) nm cable at heater shall have listed bushing or grommet, 334.80 ampacity of cable over panel shall be adjusted if foamed, 300.4(D) cable shall be 1 1/4" from edge of framing member, 210.52(A)(2) 2' wall space into kitchen shall have recpt, 314.27(A) box shall be provided for luminaire out back, BCC job id sticker shall be posted , p/s u/g n ok,see next insp. 4/5/2005 1:22:59 PM
ELE04-03672 Rough-In Permanent Service4/5/20054/5/20054/5/2005 12:00:00 AMPPASS
STEVE; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy r/i done this am, told elect he had to move phone conduit below service. p/s u/g n ok 4/5/2005 3:36:19 PM
ELE05-01084 Final4/5/20054/5/20054/5/2005 12:00:00 AMPNR
steve; Phone #: ###-#### Internet Inspection Request from: Barbara Moore not ready, reviewed depth requirement for ckt from panel to new recpts. Contr will cover enough to allow cust to park only 4/5/2005 12:23:23 PM
ELE05-01136 Permanent Service4/5/20054/5/20054/5/2005 12:00:00 AMPPASS
p/s u/g n ok