BLD18-00880
| BLD-Foundation | 4/5/2018 | 4/5/2018 | 4/6/2018 7:18:39 AM | P | PASS |
|
|
Jeremy Phone #: ###-####
|
BLD16-04571
| BLD-Final | 4/4/2018 | 4/5/2018 | 4/5/2018 3:39:04 PM | P | PASS |
|
|
Call ahead to meet // Bill Phone #: ###-####
|
BLD16-04571
| DOC - Permit Finaled | 4/5/2018 | 4/5/2018 | 4/5/2018 3:38:52 PM | P | PASS |
|
|
|
BLD18-01073
| BLD-Framing/Rough-in | 4/4/2018 | 4/5/2018 | 4/5/2018 3:09:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rick Stevens header ok/ ok to cover wall
|
BLD18-00726
| BLD-Wall Bracing | 4/5/2018 | 4/5/2018 | 4/5/2018 2:44:03 PM | P | PASS |
|
|
shear // Nate Phone #: ###-####
|
BLD18-00941
| BLD-Footing | 4/5/2018 | 4/5/2018 | 4/5/2018 2:13:55 PM | P | PASS |
|
|
call for access--Fred Phone #: ###-####
|
BLD18-00940
| BLD-Footing | 4/5/2018 | 4/5/2018 | 4/5/2018 2:13:40 PM | P | PASS |
|
|
call for access--Fred Phone #: ###-####
|
BLD18-00994
| BLD-Final | 4/4/2018 | 4/5/2018 | 4/5/2018 1:04:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Hans Weikl
|
BLD18-00994
| DOC - Permit Finaled | 4/5/2018 | 4/5/2018 | 4/5/2018 1:04:45 PM | P | PASS |
|
|
|
MIS18-00113
| BLD-Conference | 4/5/2018 | 4/5/2018 | 4/5/2018 1:04:24 PM | P | PASS |
|
|
informed home owner/ contractor not on site
|
BLD17-03812
| BLD-Aging Inspection | 4/5/2018 | 4/5/2018 | 4/5/2018 1:03:26 PM | | PASS |
|
|
no call for final.
|
BLD17-03837
| BLD-Final | 4/4/2018 | 4/5/2018 | 4/5/2018 11:29:20 AM | A | FAIL |
|
|
Qwen Phone #: ###-#### R311.7.5.1 Risers. The maximum riser height shall be 73/4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch-diameter (102 mm) sphere.
Exception: The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less.
R311.7.5.2 Treads. The minimum tread depth shall be 10 inches (254 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread’s leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch
|
BLD18-00297
| BLD-Framing/Rough-in | 4/4/2018 | 4/5/2018 | 4/5/2018 11:15:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Lierman
|
BLD17-03844
| BLD-Final | 4/4/2018 | 4/5/2018 | 4/5/2018 10:22:10 AM | A | FAIL |
|
|
Qwen- Phone #: ###-#### R312.1.1 Where required. Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side. Insect screening shall not be considered as a guard.
|
BLD17-04558
| BLD-Foundation | 4/4/2018 | 4/5/2018 | 4/5/2018 9:55:46 AM | A | PASS |
|
|
call when done- Ben Phone #: ###-####
|
MIS17-00213
| MIS-Aging Inspection | 4/5/2018 | 4/5/2018 | 4/5/2018 9:26:48 AM | | PASS |
|
|
bld complet
|
MIS17-00213
| DOC - Permit Finaled | 4/5/2018 | 4/5/2018 | 4/5/2018 9:26:27 AM | P | PASS |
|
|
|
MIS17-00439
| MIS-Aging Inspection | 4/5/2018 | 4/5/2018 | 4/5/2018 9:25:36 AM | | PASS |
|
|
plm
|
MIS17-00439
| DOC - Permit Finaled | 4/5/2018 | 4/5/2018 | 4/5/2018 9:25:17 AM | P | PASS |
|
|
|