Inspections for the day of: Friday, April 5, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02924 Final4/5/20194/5/20194/5/2019 2:23:14 PMPFAIL
will have to meet you for access, owners are out of town, so if can give me heads up, thanks Phone #: ###-#### Inspection requested via web by dennis mcneely
210.12 All devices in bedroom shall have AFCI protection(master bed out soffit cans are non AFCI protected)
ELE18-04779 Final4/5/20194/5/20194/5/2019 1:59:25 PMPFAIL
There will be guys there working. If you have any questions please feel free to contact Jason ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
210.52 each basin shall have a receptalce located within 36" of sink
*install can trim above stair way
*fix back w/p
ELE19-00174 Final4/5/20194/5/20194/5/2019 1:22:59 PMPPASS
Please call 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Ben Monasterio
Final ok
ELE19-00235 Electrical Rough-In4/4/20194/5/20194/5/2019 12:32:53 PMAPASS
Floor heat inspection
Floor heat in back bath ok to cover
ELE19-01147 Final4/4/20194/5/20194/5/2019 11:59:13 AMAPASS
Please call Jeff at ###-#### if any questions. Builder-Ron with the Pros ###-####. Thanks. Phone #: ###-#### Inspection requested via web by Andrea Creek
Life safety issue taken care of on front of building with a rate j-box
Final ok
ELE19-01066 Rough-In Permanent Service4/4/20194/5/20194/5/2019 11:44:34 AMAPASS
It will be open. If you have any questions please feel free to contact Tony ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
Will need to verify a access in hallway directly above hall outlet for electrical board connections..
Rough-in ok to cover
p/s u/g n ok
ELE18-03476 Electrical Rough-In4/4/20194/5/20194/5/2019 11:18:49 AMAPASS
Zach Phone #: ###-####
Lobby and entry hard lids and walls as noted on print ok to cover
ELE19-00909 Electrical Rough-In4/4/20194/5/20194/5/2019 10:44:16 AMAPASS
code box on bike rack is 1027, keys for 103 or north doors Phone #: ###-#### Inspection requested via web by David Nelson
Walls only ok to cover
Will need to verify on ceilng inspection Panel A in mechanical room conduit has no more 360 degrees in bend, as of now it has more then allowed and needs a puls box....
ELE19-01180 Final4/4/20194/5/20194/5/2019 9:52:59 AMAPASS
Please call Kaden with any questions, please call our office before heading that way ###-#### Phone #: ###-#### Inspection requested via web by William Salts
Mini split unit install final ok
ELE19-01196 Final4/4/20194/5/20194/5/2019 9:33:55 AMACANC
Phone #: ###-#### Inspection requested via web by Same Electric
No final at this time just P/S
ELE19-01196 Permanent Service4/5/20194/5/20194/5/2019 9:33:43 AMPPASS
Phone #: ###-#### Inspection requested via web by Same Electric
p/s o/h rec ok