Inspections for the day of: Tuesday, April 6, 2004.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-00301 ELE-Aging Inspection4/6/20044/6/20044/6/2004 12:00:00 AM NR
This is for bathroom only 4/8/2004 4:55:18 PM
ELE04-00317 Permanent Service4/6/20044/6/20044/6/2004 12:00:00 AMAPASS
P/S O/H R Ok
ELE04-00934 Electrical Rough-In4/5/20044/6/20044/6/2004 12:00:00 AMAPART
Alex; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
U/G to garage ok 4/6/2004 10:31:36 AM
ELE04-00317 Final4/5/20044/6/20044/6/2004 12:00:00 AMAFAIL
PLease call 1/2 hour prior to inspetion///ED; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
I don't have enough access to inspect the hot tub.
430.14 Location of Motors.
(A) Ventilation and Maintenance. Motors shall be located so that adequate ventilation is provided and so that maintenance, such as lubrication of bearings and replacing of brushes, can be readily accomplished.

210.70 Lighting Outlets Required.
Lighting outlets shall be installed where specified in 210.70(A), (B), and (C).
(A) Dwelling Units. In dwelling units, lighting outlets shall be installed in accordance with 210.70(A)(1), (2), and (3).
Light required by back door.

110.2 Approval.
The conductors and equipment required or permitted by this Code shall be acceptable only if approved,
and such approvals are based on tests and listings of testing laboratories.
Top add-on to hot tub shall be listed or field evaluated.

680.26 Bonding.is incomplete
(A) Performance. The bonding required by this section shall be installed to eliminate voltage gradients in the pool area as prescribed.
FPN:This section does not require that the 8 AWG or larger solid copper bonding conductor be extended or attached to any remote panelboard, service equipment, or any electrode.

334.30 Securing and Supporting.
Nonmetallic-sheathed cable shall be secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable at intervals not exceeding 1.4 m (41/2 ft) and within 300 mm (12 in.) of every cabinet, box, or fitting. Flat cables shall not be stapled on edge.
In basement by light fixture above dryer recep..

110.12 Mechanical Execution of Work.
Electrical equipment shall be installed in a neat and workmanlike manner.
(A) Unused Openings. Unused cable or raceway openings in boxes, raceways, auxiliary gutters, cabinets, cutout boxes, meter socket enclosures, equipment cases, or housings shall be effectively closed
In panel in stairway. Also install inhibitor on ground wire and insure that all strands are in tact.
4/6/2004 10:03:29 AM
ELE04-00874 Electrical Rough-In4/5/20044/6/20044/6/2004 12:00:00 AMAPASS
jonese; Phone #: ###-#### Internet Inspection Request from: Darla Downs
ELE04-00505 Electrical Rough-In4/5/20044/6/20044/6/2004 12:00:00 AMAPART
dan; Phone #: ###-#### Internet Inspection Request from: Darla Downs
ceiling ANOP 4/6/2004 8:53:11 AM
ELE04-00893 Electrical Rough-In4/6/20044/6/20044/6/2004 12:00:00 AMPCANC
Scheduled by a contractor via Hello! on 4/6/2004 at 7:35:09 AM. Contact: ###-####.
ELE04-00905 Electrical Rough-In4/6/20044/6/20044/6/2004 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 4/6/2004 at 7:35:09 AM. Contact: ###-####.
west half ok 4/6/2004 1:50:48 PM
ELE04-00522 Electrical Rough-In4/6/20044/6/20044/6/2004 12:00:00 AMPPASS
trench inspection for pool light///bernice; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
trench ok 4/6/2004 3:46:17 PM
ELE04-00821 Permanent Service4/6/20044/6/20044/6/2004 12:00:00 AMPFAIL
harold; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
locate water where it enters the building and bond it appropriately and remove grounding electrode conductor from metal raceway. 4/6/2004 3:49:43 PM
ELE04-00967 Electrical Rough-In4/6/20044/6/20044/6/2004 12:00:00 AMPPASS
###-####- bob
ELE03-03980 Electrical Rough-In4/6/20044/6/20044/6/2004 12:00:00 AMPPART
Upher inspection please////glenn; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ok for concrete 4/6/2004 3:46:52 PM
ELE04-00317 Final4/6/20044/6/20044/6/2004 12:00:00 AMPPART
###-#### terry
all inside corrections were made.
Light location and hot tub inspection and listing for cover remain undone 4/6/2004 1:53:27 PM