MEC15-01446
| Final | 4/6/2015 | 4/6/2015 | 4/6/2015 4:30:14 PM | P | PASS |
|
|
HOME OWNER WILL THERE
|
MEC15-00093
| Final | 4/6/2015 | 4/6/2015 | 4/6/2015 4:23:24 PM | P | FAIL |
|
|
CALLED HOME OWNER TO SEE IF C.O. DETECTORS WERE INSTALLED...CARBON MONOXIDE DETECTORS HAVE NOT BEEN INSTALLED...PLEASE TAKE CARE OF THIS AND RESCHEDULE..THANKS
|
MEC15-01446
| Conference | 4/5/2015 | 4/6/2015 | 4/6/2015 3:53:36 PM | P | PEND |
|
|
owner says they will be home after 2:39 pm, their # is ###-#### Phone #: ###-#### >> Inspection requested via web by bob pond..THIS SHOULD HAVE BEEN A FINAL...NOT A CONFERENCE
|
MEC15-00937
| Final | 4/6/2015 | 4/6/2015 | 4/6/2015 3:43:32 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Otero
|
MEC15-00854
| Conference | 4/6/2015 | 4/6/2015 | 4/6/2015 3:36:36 PM | P | PEND |
|
|
MEET DIXIE AT 1:30...MET WITH BILL TO CHECK ON THIS JOB..HE WILL TALK TO SAM Z. ABOUT IT.
|
MEC15-01365
| Rough-in | 4/6/2015 | 4/6/2015 | 4/6/2015 2:58:14 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell..HEAT SHIELD OUTSIDE LOOKS BACKWARDS
|
GCM15-00055
| GCM-Final | 4/3/2015 | 4/6/2015 | 4/6/2015 11:52:25 AM | A | PASS |
|
|
Dave ###-####
|
MEC15-01087
| Rough-in | 4/3/2015 | 4/6/2015 | 4/6/2015 11:13:38 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart...OUTSIDE AIR MUST TIE INTO R/A PLENUM UPSTREAM OF THE FILTER WITH AN ACCESSIBLE BACK DRAFT DAMPER ...NEED TO SLEEVE B-VENT IN ATTIC AND NEED 1" CLEARANCE AT ROOF..BATH EXHAUST TO BE 3' FROM OPEN WINDOW..MOVE SUPPLY RUN IN GREAT ROOM ABOVE THE ELEC CORD OR IT WILL GET SMASHED BY THE SHEETROCK
|
MEC15-01087
| Pressure Test | 4/3/2015 | 4/6/2015 | 4/6/2015 11:09:28 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart..20lb gas ok
|
GCM15-00060
| GCM-Final | 4/3/2015 | 4/6/2015 | 4/6/2015 10:37:42 AM | A | NR |
|
|
Stan ###-#### - requested 30min call ahead..talked to Bill and he wants to wait until the fire inspectors signs off..i called stan and let him know.
|
MEC15-01237
| Final | 4/3/2015 | 4/6/2015 | 4/6/2015 10:27:11 AM | A | PASS |
|
|
Final on class one exhaust hood system. call Dave ###-#### Phone #: ###-#### >> Inspection requested via web by Dave DeChambeau..signed the card
|
MEC15-01422
| Final | 4/6/2015 | 4/6/2015 | 4/6/2015 10:26:23 AM | A | PASS |
|
|
Call Dave for access Phone #: ###-#### >> Inspection requested via web by Brandon Rohricht..signed the card
|
MEC15-01224
| Final | 4/3/2015 | 4/6/2015 | 4/6/2015 9:20:32 AM | A | FAIL |
|
|
Daniel ###-#### will meet you at 9:30am with ladder. Phone #: ###-#### >> Inspection requested via web by Krista Boss..no access into the church
|
MEC15-00854
| Rough-in | 4/3/2015 | 4/6/2015 | 4/6/2015 9:17:33 AM | A | NR |
|
|
Doug Phone #: ###-####..building permit is not issued
|
MEC15-01224
| Final | 4/3/2015 | 4/6/2015 | 4/3/2015 3:35:17 PM | A | CANC |
|
|
Meet with Eric at 9:30 am for ladder. ###-#### Thanks Phone #: ###-#### >> Inspection requested via web by Allie Courter Inspection cancelled from web by: Krista Boss
|