ELE13-00731
| ELE-Aging Inspection | 4/6/2016 | 4/6/2016 | 4/6/2016 3:57:23 PM | | PASS |
|
|
Owner refusing to comply
|
ELE16-01066
| Final | 4/5/2016 | 4/6/2016 | 4/6/2016 3:45:06 PM | P | FAIL |
|
|
would like call ahead; Jim Phone #: ###-#### 100- Multi-wire branch circuit shall be install to have voltage between ungrounded conductors. 240.4- Max overcurrent device on 14 ga. wire shall not exceed 15 amp. 210.52- Each wall 24" or wider shall have a receptacle outlet installed. bedroom 300.15- Ceck small hall outside bed for light wire in attic. Shall be installed in a box. 408.7- Unused breaker openings shall be closed. Replace GFCI on outsid of addition. Remove underground to receptacle on fence.
|
ELE15-02077
| Final | 4/5/2016 | 4/6/2016 | 4/6/2016 2:51:33 PM | P | PASS |
|
|
Please call for contact information for First Team Restoration if needed - Kendra Phone #: ###-#### Meter had been taken loose to install siding. Meter base resecured. Final ok
|
ELE16-00521
| Electrical Rough-In | 4/6/2016 | 4/6/2016 | 4/6/2016 2:22:45 PM | P | PASS |
|
|
Chris is the contact his cell no. ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates All wall except managers office rough in ok cover
|
ELE16-00810
| Electrical Rough-In | 4/6/2016 | 4/6/2016 | 4/6/2016 12:44:12 PM | P | PASS |
|
|
Megan Phone #: ###-#### photos taken, BLD received, discussed future baseboard shall not be located under receptacle. Enclosed patio wired in 20 amp rough in ok cover
|
ELE16-01072
| Temporary Service | 4/6/2016 | 4/6/2016 | 4/6/2016 12:14:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s o/h n ok
|
ELE16-00975
| Conference | 4/6/2016 | 4/6/2016 | 4/6/2016 11:30:51 AM | P | FAIL |
|
|
BLD under review, ELE, MECH, exist no PLM permit found.
|
ELE15-03901
| Electrical Rough-In | 4/5/2016 | 4/6/2016 | 4/6/2016 11:10:07 AM | A | PASS |
|
|
Contact Joey for inspection of exterior walls on 8th floor and walls in executive suite (penthouse). Phone #: ###-#### Inspection requested via web by Rafael Castillo Discussed providing an access to a airhandler disconnecting means that will be located on each floorcovered by a wall. Asked that access be around 24" wide to give service personel a visual of area. 8th floor marked in pink exterior wall at southwest corner. 9th floor all perimeter walls only. Penthouse suite on 10th south 1/2 lounge walls. As noted and marked on prints in pink wall rough in ok cover
|
ELE16-01010
| Electrical Rough-In | 4/5/2016 | 4/6/2016 | 4/6/2016 9:38:56 AM | A | PASS |
|
|
code is 193 Phone #: ###-#### Inspection requested via web by Shaun Kirkman Access panel will be provided for junction box above hardlid south edge of front window. Walls and hardlid rough in ok cover
|
ELE16-00920
| Permanent Service | 4/5/2016 | 4/6/2016 | 4/6/2016 8:40:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve ragan 2 locations ok as per Daryl Degrange. 1 ped east entrance on north side of road 1 ped west entrance on south side of road p/s u/g n ok
|