ELE13-00731 ELE-Aging Inspection4/6/20164/6/20164/6/2016 3:57:23 PM PASS
Owner refusing to comply
ELE16-01066 Final4/5/20164/6/20164/6/2016 3:45:06 PMPFAIL
would like call ahead; Jim Phone #: ###-####
100- Multi-wire branch circuit shall be install to have voltage between ungrounded conductors.
240.4- Max overcurrent device on 14 ga. wire shall not exceed 15 amp.
210.52- Each wall 24" or wider shall have a receptacle outlet installed. bedroom
300.15- Ceck small hall outside bed for light wire in attic. Shall be installed in a box.
408.7- Unused breaker openings shall be closed.
Replace GFCI on outsid of addition.
Remove underground to receptacle on fence.
ELE15-02077 Final4/5/20164/6/20164/6/2016 2:51:33 PMPPASS
Please call for contact information for First Team Restoration if needed - Kendra Phone #: ###-#### Meter had been taken loose to install siding. Meter base resecured. Final ok
ELE16-00521 Electrical Rough-In4/6/20164/6/20164/6/2016 2:22:45 PMPPASS
Chris is the contact his cell no. ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates
All wall except managers office rough in ok cover
ELE16-00810 Electrical Rough-In4/6/20164/6/20164/6/2016 12:44:12 PMPPASS
Megan Phone #: ###-#### photos taken, BLD received, discussed future baseboard shall not be located under receptacle. Enclosed patio wired in 20 amp rough in ok cover
ELE16-01072 Temporary Service4/6/20164/6/20164/6/2016 12:14:14 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s o/h n ok
ELE16-00975 Conference4/6/20164/6/20164/6/2016 11:30:51 AMPFAIL
BLD under review, ELE, MECH, exist no PLM permit found.
ELE15-03901 Electrical Rough-In4/5/20164/6/20164/6/2016 11:10:07 AMAPASS
Contact Joey for inspection of exterior walls on 8th floor and walls in executive suite (penthouse). Phone #: ###-#### Inspection requested via web by Rafael Castillo
Discussed providing an access to a airhandler disconnecting means that will be located on each floorcovered by a wall. Asked that access be around 24" wide to give service personel a visual of area.
8th floor marked in pink exterior wall at southwest corner. 9th floor all perimeter walls only. Penthouse suite on 10th south 1/2 lounge walls. As noted and marked on prints in pink wall rough in ok cover
ELE16-01010 Electrical Rough-In4/5/20164/6/20164/6/2016 9:38:56 AMAPASS
code is 193 Phone #: ###-#### Inspection requested via web by Shaun Kirkman
Access panel will be provided for junction box above hardlid south edge of front window. Walls and hardlid rough in ok cover
ELE16-00920 Permanent Service4/5/20164/6/20164/6/2016 8:40:52 AMAPASS
Phone #: ###-#### Inspection requested via web by steve ragan
2 locations ok as per Daryl Degrange.
1 ped east entrance on north side of road
1 ped west entrance on south side of road
p/s u/g n ok