Inspections for the day of: Monday, April 8, 2002.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-02401 BLD-Framing/Rough-in4/5/20024/8/20024/8/2002 12:00:00 AMAPART
a-35s 48 " oc at center drag strut/draft stop1. (Fire blocks and draft stops) In combustible construction, fireblocking and draftstopping shall be installed to cut off all concealed draft openings (both vertical and horizontal) and shall form an effective barrier between floors, between a top story and a roof or attic space, and shall subdivide attic spaces, concealed roof spaces and floor-ceiling assemblies. The integrity of all fire blocks and draft stops shall be maintanined. (1997 UBC 708.1)

2. DRAFT STOPS - When there is usable space above and below the concealed space of a floor-ceiling assembly in a single-family dwelling, draft stops shall be installed so that the area of the concealed space does not exceed 1,000 square feet. Draftstopping shall divide the concealed space into approximately equal areas. (1997 UBC 708.3.1.1.1) Draftstopping materials shall not be less than 1/2-inch gypsum board, 3/8-inch wood structural panel or other approved materials adequately supported. Openings in the partitions shall be protected by self-closing doors with automatic latches constructed as required for the partitions. Ventilation of concealed roof spaces shall be maintained. (1997 UBC 708.3.1.3)
BLD02-00270 BLD-Framing/Rough-in4/5/20024/8/20024/8/2002 12:00:00 AMAPART
###-#### MIKE c/no ceilling made ok 4/8/2002 11:20:13 AM
BLD01-01647 BLD-Framing/Rough-in4/5/20024/8/20024/8/2002 12:00:00 AMANR
###-#### MIKE (SHELL)
BLD02-00423 BLD-Framing/Rough-in4/5/20024/8/20024/8/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 04/05/2002 at 11:42:24. Contact: ###-####.
MIS02-00068 BLD-Final4/5/20024/8/20024/8/2002 12:00:00 AMPFAIL
fn insp -jeff- ###-#### dead bolts/flush bolts/door signage at main entry / secure mez from access. 4/8/2002 4:26:22 PM
BLD01-00645 BLD-Framing/Rough-in4/5/20024/8/20024/8/2002 12:00:00 AMPCANC
Scheduled by a contractor via Hello! on 04/05/2002 at 08:09:10. Contact: ###-####.
BLD02-00680 BLD-Concrete4/8/20024/8/20024/8/2002 12:00:00 AMPPASS
###-#### DON
BLD01-01093 BLD-Framing/Rough-in4/8/20024/8/20024/8/2002 12:00:00 AMPNR
ernie - ###-#### fr
BLD01-02222 BLD-Concrete4/8/20024/8/20024/8/2002 12:00:00 AMPNR
###-#### BRIAN