Inspections for the day of: Wednesday, April 9, 2008.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00339 Final4/9/20084/9/20084/9/2008 3:52:23 PMPPASS
Garage code 2008 Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok to final
ELE08-00725 Final4/9/20084/9/20084/9/2008 3:04:24 PMPPASS
robert Phone #: ###-#### called contractor, ok to final
ELE07-03561 Rough-In Permanent Service4/8/20084/9/20084/9/2008 2:14:19 PMPPASS
mark Phone #: ###-#### p/s o/h rec ok
ELE08-00845 Final4/8/20084/9/20084/9/2008 1:01:20 PMPFAIL
adding circuit for furnace and heat pump, any questions please call lead tech for that job; Owen ###-####. Phone #: ###-#### Internet Inspection Request from: Yolanda Morris called left correction notice, nec 356.26 there shall not be over 4 quarter bends in lfnc, 348.30 shall strap flex within 12" of termination point, 422.31 shall provide disconnect in sight of appliance or provide breaker lock-out, 300.4 conductors shall be protected from damage, 110.2 (B) listed equipment shall be installed per manufacturers instructins, gfci has open neutral, recpt has h&n reversed
ELE08-00865 Permanent Service4/9/20084/9/20084/9/2008 12:53:18 PMPPASS
Robert; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s u/g rec ok
ELE08-00675 Final4/8/20084/9/20084/9/2008 11:08:12 AMAPASS
kenny Phone #: ###-#### x 3322 ok to final, signed structural card
ELE08-00822 Rough-In Permanent Service4/7/20084/9/20084/9/2008 10:30:11 AMAPASS
Craig Phone #: ###-#### ric ok, p/s o/h rec ok (to new new pole with meter main closer to pole)
ELE08-00855 Electrical Rough-In4/8/20084/9/20084/9/2008 9:59:22 AMAPART
cover inspection in garage only Phone #: ###-#### Internet Inspection Request from: gary batten garage only ok to cover
ELE08-00696 Rough-In Permanent Service4/8/20084/9/20084/9/2008 9:28:11 AMAPASS
Calvin; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ric ok both units, p/s u/g n ok, 2 meters
ELE08-00828 Electrical Rough-In4/8/20084/9/20084/9/2008 8:35:18 AMAPASS
MORGAN UFFER GROUND Phone #: ###-#### Internet Inspection Request from: Sean DeLacy concrete encased electrode ok to pour east unit by peasley street
ELE08-00857 Electrical Rough-In4/8/20084/9/20084/9/2008 8:12:03 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok
ELE08-00857 Final4/9/20084/9/20084/9/2008 8:11:52 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok o final