Inspections for the day of: Tuesday, April 9, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02411 ELE-Aging Inspection4/9/20134/9/20134/16/2013 2:59:41 PM DONE
Drove by still under construction
ELE12-01710 Electrical Rough-In4/9/20134/9/20134/9/2013 3:27:01 PMPPASS
Contact: Wes Powell - wall rough-in please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Bathrooms floors 2-6-7-8 rough in ok cover
ELE13-00845 Electrical Rough-In4/8/20134/9/20134/9/2013 2:07:25 PMPPASS
Will you call Goddy about one hour before you go he can meet and let you in. Floor heat and sub-panel. Phone #: ###-#### >> Inspection requested via web by Neal Rumsey
Kitchen floor heat rough in ok cover
GCE13-00013 GCE-Final4/8/20134/9/20134/9/2013 1:01:00 PMPFAIL
(Mandatory Inspection) Daniel ###-####; call for gate code
210.8 All kitchen counter top recepticals shall be GFCI protected.
314.20 Utility recepticals- wall constructed of combustible materials shall be finished with spark or extension rings.
2nd notice of temp poles on property with blank of device missing leaving bussing exposed.
GCE13-00056 GCE-Temporary Service4/9/20134/9/20134/9/2013 12:22:47 PMPPASS
###-#### t/s u/g n ok
ELE11-02806 Electrical Rough-In4/9/20134/9/20134/9/2013 11:13:31 AMAPASS
ceiling inspection on the west hallway behind the council chambers Phone #: ###-#### >> Inspection requested via web by Shawna Gates rough in west and south hall ceiling ok
ELE13-00697 Electrical Rough-In4/8/20134/9/20134/9/2013 10:15:21 AMAPASS
Need an ok to cover the floor heat system in the master bath. Phone #: ###-#### >> Inspection requested via web by John Edwards
Floor rough in ok cover
ELE13-00704 Final4/8/20134/9/20134/9/2013 9:55:09 AMAPASS
Phone #: ###-#### >> Inspection requested via web by JENNY EMEL
No card posted Final ok
GCE13-00048 GCE-Rough-In4/4/20134/9/20134/9/2013 9:29:58 AMAPASS
Henry ###-#### Lighting retro. UL listed materials confirme rough in ok
ELE13-00840 Final4/8/20134/9/20134/9/2013 9:10:46 AMAPASS
Homeowner will be at residence. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot Final ok
ELE13-00840 Permanent Service4/9/20134/9/20134/9/2013 9:10:17 AMPPASS
Homeowner will be at residence. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot p/s o/h n ok
ELE13-00732 Final4/8/20134/9/20134/9/2013 8:48:55 AMAPASS
Added two new circuits in and out of the garage. One is for the new gas furnace in the garage. The other is for the heat pump out the back porch. The garage door will be open for easy access. Please call when you are done so I can have the garage door closed. Thank You Phone #: ###-#### >> Inspection requested via web by Thomas Jenkins Final ok
ELE13-00732 Electrical Rough-In4/9/20134/9/20134/9/2013 8:46:15 AMPPASS
Added two new circuits in and out of the garage. One is for the new gas furnace in the garage. The other is for the heat pump out the back porch. The garage door will be open for easy access. Please call when you are done so I can have the garage door closed. Thank You Phone #: ###-#### >> Inspection requested via web by Thomas Jenkins Rough in ok