ELE19-00023
| Final | 4/9/2019 | 4/9/2019 | 4/9/2019 3:23:55 PM | P | PASS |
|
|
Lori Phone #: ###-#### Final ok
|
ELE19-00023
| Electrical Rough-In | 4/9/2019 | 4/9/2019 | 4/9/2019 3:06:44 PM | P | PASS |
|
|
Lori Phone #: ###-#### Listing and disconnecting means confirmed. Rough in ok
|
ELE18-04138
| Electrical Rough-In | 4/9/2019 | 4/9/2019 | 4/9/2019 2:55:51 PM | P | PASS |
|
|
Ceilings for cover Phone #: ###-#### Inspection requested via web by Mike McCarrel Ceilings rough in ok cover
|
ELE18-01608
| Conference | 4/9/2019 | 4/9/2019 | 4/9/2019 2:55:34 PM | P | DONE |
|
|
Discussed ceilings in bathrooms of EO Wilson building. Access shall be provided to fit a full body above ceiling to access emergency ballast of luminaires in bathroom and bathroom entrance. Ceiling support system shall not be used to support luminaires, cables, or conduits unless manufacturers instructions state other wise
|
ELE19-01001
| Final | 4/9/2019 | 4/9/2019 | 4/9/2019 2:29:47 PM | P | PASS |
|
|
Jose- please call if any questions Phone #: ###-#### Final ok
|
ELE19-01201
| Permanent Service | 4/8/2019 | 4/9/2019 | 4/9/2019 2:29:16 PM | A | PASS |
|
|
Please let me know when done Phone #: ###-#### Inspection requested via web by Thomas wilson p/s u/g n ok
|
ELE19-01075
| Electrical Rough-In | 4/9/2019 | 4/9/2019 | 4/9/2019 2:02:57 PM | P | PASS |
|
|
Lock box code 8463 located on the hand rail in stairwell. Looking for OK to cover floor box in conference room, and wall in break room. Phone #: ###-#### Inspection requested via web by Dean Gernaat Area noted rough in ok cover
|
ELE19-01043
| Rough-In Permanent Service | 4/9/2019 | 4/9/2019 | 4/9/2019 1:49:40 PM | P | PASS |
|
|
Please call 30min in advance so I can meet you there. Phone #: ###-#### Inspection requested via web by Jason Wicks Wrong number listed correct number ###-####. Electrical contractor has replaced all wiring associated with kitchen, small appliance circuits and seperated 15 and 20 amp circuits so correct wire size is present where needed. As per Daryl DeGrange if electrical contractor takes responsibility for wiring in kitchen and bathroom areas additional drywall does not need to be removed. Electrical contractor confirmed he would be responsible for all wiring in kitchen and bathroom areas. 250.64- Grounding electrode conductors shall be continuous to main disconnecting means. 250.140- Range and dryer receptacles shall be 4 wire, appliance frames shall not be bonded through grounded conductor. Rough in of patch holes ok cover. p/s o/h rec ok
|
ELE19-01202
| Rough-In Permanent Service | 4/9/2019 | 4/9/2019 | 4/9/2019 12:45:37 PM | P | PASS |
|
|
Call with any questions thank you Phone #: ###-#### Inspection requested via web by kim grundhauser OKed with general contractor promise not to foam seal prior to inspection again. Nice job! Rough in ok cover p/s u/g n ok
|
ELE19-01246
| Permanent Service | 4/8/2019 | 4/9/2019 | 4/9/2019 11:21:44 AM | A | PASS |
|
|
Please let me know when done Phone #: ###-#### Inspection requested via web by Thomas wilson p/s u/g n ok
|
ELE19-00350
| Final | 4/8/2019 | 4/9/2019 | 4/9/2019 10:32:01 AM | A | PASS |
|
|
Will Phone #: ###-#### Final ok
|
ELE19-00350
| Electrical Rough-In | 4/9/2019 | 4/9/2019 | 4/9/2019 10:31:40 AM | P | PASS |
|
|
Will Phone #: ###-#### Grid rough in ok cover
|
ELE19-01166
| Temporary Service | 4/8/2019 | 4/9/2019 | 4/9/2019 10:01:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE19-01202
| Rough-In Permanent Service | 4/8/2019 | 4/9/2019 | 4/9/2019 9:58:21 AM | A | FAIL |
|
|
call with any questions, thank you Phone #: ###-#### Inspection requested via web by kim grundhauser BCC 4 05 23- It shall be unlawful for any person, to cover in any way or conceal any electrical wiring ,cable, conduit or other equipment until the same has been inspected and approved by an electrical inspector. Remove all caulking around boxes and foam applied to bored holes where wiring is run and recall
|
ELE19-00602
| Electrical Rough-In | 4/8/2019 | 4/9/2019 | 4/9/2019 9:21:25 AM | A | PASS |
|
|
Cover for NE concrete walls. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen N.E. corner wall pour rough in ok cover
|