Inspections for the day of: Tuesday, May 1, 2007.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01551 Electrical Rough-In4/30/20075/1/20075/1/2007 3:57:02 PMPPART
joe - early afternoon, 3rd floor guest rm ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met contr, power except panels ok 3rd floor rooms, needs to do lv, move foreign piping over panels, add drip shields, finish lv, will call for cover when ready
ELE07-01503 Electrical Rough-In5/1/20075/1/20075/1/2007 3:03:08 PMPFAIL
trench inspection Phone #: ###-#### Internet Inspection Request from: DJ Carman met contr, called elect contractor, left corr notice, nec 680.10 min burial depth of pvc shall be 18" within 5' of pool, 300.5 min burial depth pvc shall be 18" except under slab shall be 12"
ELE07-01217 Permanent Service5/1/20075/1/20075/1/2007 2:03:08 PMPPASS
bruce; Phone #: ###-#### Internet Inspection Request from: Victoria Beall p/s,exst meter pak, n, ok, 2 meters
ELE07-01084 Electrical Rough-In4/30/20075/1/20075/1/2007 12:55:58 PMPPASS
doug; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met contr, ric ok, told to add front recpt
ELE07-00043 Final4/30/20075/1/20075/1/2007 10:15:57 AMAPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr to survey loose recpts and cover to be flush with recpts, ok to final
ELE07-01557 Conference4/30/20075/1/20075/1/2007 9:11:18 AMADONE
Chris ###-#### met owner to talk about service for new garage and sub-feed to house
ELE07-01361 Electrical Rough-In5/1/20075/1/20075/1/2007 8:40:33 AMACANC
Please meet with Jerry Kinch, on-site. Cell ####-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson met elect see conf
ELE07-01361 Conference5/1/20075/1/20075/1/2007 8:38:32 AMADONE
Please meet with Jerry Kinch, on-site. Cell ####-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson met elect to review outlet spacing and subpanels
ELE07-01554 Temporary Service4/30/20075/1/20075/1/2007 7:45:54 AMAPASS
zane ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith t/s o/h n ok