ELE14-01094
| Permanent Service | 5/1/2014 | 5/1/2014 | 5/1/2014 5:03:46 PM | P | PASS |
|
|
p/s o/h rec ok tree trimmer dropped limb on old service drop
|
ELE14-00532
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 4:45:00 PM | P | PART |
|
|
ben - please call 1/2 hr prior Phone #: ###-#### rough in ok kitchen and upst. bath only
|
ELE14-00319
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 3:46:01 PM | P | PASS |
|
|
Ceiling Grids partial Phone #: ###-#### >> Inspection requested via web by Kristopher Wilson rough in ceilings ok rm's 117,118 and 119.. Borders only throughout ok
|
ELE14-01090
| Conference | 5/1/2014 | 5/1/2014 | 5/1/2014 3:15:54 PM | P | DONE |
|
|
Please call Aaron when on your way. ###-#### thank you. Phone #: ###-#### >> Inspection requested via web by Clay Morgan discuss adding to old overloaded 60 amp service. recent electrical added by ultimate electric for A-1 heating equipt.
|
ELE14-01083
| Final | 4/30/2014 | 5/1/2014 | 5/1/2014 2:24:21 PM | A | PASS |
|
|
help yourself Phone #: ###-#### >> Inspection requested via web by Douglas Moyle final on 20 HP pump ok
|
ELE14-01089
| Final | 5/1/2014 | 5/1/2014 | 5/1/2014 1:57:09 PM | P | CANC |
|
|
trench insp from house to detached garage Phone #: ###-#### >> Inspection requested via web by Mike Cole needed rough in u.g. insp.
|
ELE14-01089
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 1:56:14 PM | P | PASS |
|
|
trench insp from house to detached garage Phone #: ###-#### >> Inspection requested via web by Mike Cole rough in u.g. ok to cover secondary and garage conduits
|
ELE14-00092
| Final | 4/30/2014 | 5/1/2014 | 5/1/2014 1:28:04 PM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson 334.15 B nm cable needs to be protected. mstr. bath recetacles loose and can't find GFCI to reset them
|
ELE14-00983
| Final | 4/30/2014 | 5/1/2014 | 5/1/2014 12:42:26 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by steve ragan final ok
|
ELE14-00999
| Conference | 4/30/2014 | 5/1/2014 | 5/1/2014 11:03:05 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton needed rough in insp also
|
ELE14-00999
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 11:03:02 AM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton needed conference and rough in partial insp. for bar north wall and bar pony wall and dishwasing room walls.
|
ELE14-00999
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 11:02:33 AM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton needed conf. and rough in insp. bar north wall and bar pony wall and dishwashing room walls only
|
ELE14-00819
| Final | 5/1/2014 | 5/1/2014 | 5/1/2014 10:00:43 AM | A | PASS |
|
|
final inspection Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe final ok left message to confirm fault current rating from Idaho power's x-former within 25 foot of main to see if it exceeds 10,000 aic
|
ELE14-01086
| Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 9:09:56 AM | A | PASS |
|
|
please prior to arrival for access Phone #: ###-#### >> Inspection requested via web by Patrick Paz rough in ok
|
ELE14-01085
| Final | 4/30/2014 | 5/1/2014 | 5/1/2014 8:46:52 AM | A | DONE |
|
|
Need to talk about room classification and electrical install Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes needed conference
|
ELE14-01085
| Conference | 5/1/2014 | 5/1/2014 | 5/1/2014 8:46:24 AM | P | DONE |
|
|
Need to talk about room classification and electrical install Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes discuss indoor pool requirements to meet code
|