MEC17-00968
| Rough-in | 5/1/2017 | 5/1/2017 | 5/1/2017 3:13:49 PM | P | FAIL |
|
|
6 Units Fire Damper Phone #: ###-#### Inspection requested via web by Aaron Allred-Need to use a minimum of 16 gauge angle on fire dampers. Need to use approved straping on metal ducting and dryer venting. Need to support dryer venting every 4' and metal ducting every 10'.
|
MEC17-00908
| Pressure Test | 4/27/2017 | 5/1/2017 | 5/1/2017 3:10:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney-20 lb gas test pass.
|
MEC17-00908
| Rough-in | 4/27/2017 | 5/1/2017 | 5/1/2017 3:09:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC17-01555
| Rough-in | 5/1/2017 | 5/1/2017 | 5/1/2017 3:09:48 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ed Ables-Need to uncover for inspection and need installation instructions.
|
PLM17-01287
| Plumbing Rough-in | 4/28/2017 | 5/1/2017 | 5/1/2017 1:47:54 PM | P | PASS |
|
|
JOB # 19064. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-01229
| Plumbing Rough-in | 4/28/2017 | 5/1/2017 | 5/1/2017 1:47:32 PM | P | FAIL |
|
|
JOB # 19054. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes-DWV test fail. Need to fix or remove stress on abs fitting due to electricians.
|
PLM17-01402
| Storm Drains | 4/28/2017 | 5/1/2017 | 5/1/2017 11:21:58 AM | A | PART |
|
|
Storm Drain Inspection Phone #: ###-#### Inspection requested via web by Luke Moody-1st 20' of storm drain from interceptor to building installed.
|
PLM17-01429
| Plumbing Rough-in | 4/30/2017 | 5/1/2017 | 5/1/2017 11:20:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Stephenson
|
PLM17-01449
| Water and/or Sewer | 4/28/2017 | 5/1/2017 | 5/1/2017 10:29:17 AM | A | PASS |
|
|
please call joel first Phone #: ###-#### Inspection requested via web by john brown-Sprinkler tee installed with waterline.
|
PLM17-01449
| DOC - Permit Finaled | 5/1/2017 | 5/1/2017 | 5/1/2017 10:28:41 AM | P | PASS |
|
|
|
PLM17-01450
| Water and/or Sewer | 4/30/2017 | 5/1/2017 | 5/1/2017 10:11:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM17-01450
| DOC - Permit Finaled | 5/1/2017 | 5/1/2017 | 5/1/2017 10:11:28 AM | P | PASS |
|
|
|
PLM17-01444
| Sprinkler (Final) | 4/28/2017 | 5/1/2017 | 5/1/2017 9:49:17 AM | A | PASS |
|
|
Jason Phone #: ###-####
|
PLM17-00978
| Final | 4/28/2017 | 5/1/2017 | 5/1/2017 9:25:35 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by david colburn-No access, left notice
|
PLM17-00614
| Water and/or Sewer | 4/28/2017 | 5/1/2017 | 5/1/2017 8:52:20 AM | A | PART |
|
|
4in potable water line, North West area of building 51 Phone #: ###-#### Inspection requested via web by Craig Fischer-4" water main from building out to valve box installed. Need to install 8" water main from valve box to 8' existing main and test all 4" & 8" when complete.
|
PLM16-01448
| PLM-Aging Inspection | 5/1/2017 | 5/1/2017 | 5/1/2017 6:15:12 AM | | PART |
|
|
No calls
|