BLD18-03098
| BLD-Final | 5/1/2020 | 5/1/2020 | 5/1/2020 5:09:50 PM | P | FAIL |
|
|
No approved plans or permit found on site... Address to be readily visable... Per 308.4.5- Glazing and wet sufaces- bathroom 1, tub area to be tempered... Per 314.3 Smoke alarms- to be outside each seperate sleeping area in the immediate vicinity of the bedroom...
|
BLD19-02847
| BLD-Framing/Rough-in | 4/30/2020 | 5/1/2020 | 5/1/2020 5:05:09 PM | P | PASS |
|
|
Virtual inspection due to Covid-19...
|
BLD19-04333
| BLD-Framing/Rough-in | 4/30/2020 | 5/1/2020 | 5/1/2020 11:47:42 AM | A | FAIL |
|
|
Addres to be readily visable... Provide truss Engineering... Provide revised Engineering for compromised shear wall, with beam calcs, see plans pg. 4... Per plans- beam and columns to be as per schedule, see plans... OK to insulate...
|
BLD20-01005
| BLD-Footing | 4/30/2020 | 5/1/2020 | 5/1/2020 11:44:31 AM | A | PEND |
|
|
Provide Geo soils approval, abandoned backfilled pool found in footings location...
|
BLD18-02185
| BLD-Aging Inspection | 5/1/2020 | 5/1/2020 | 5/1/2020 11:29:30 AM | | DEFR |
|
|
|
BLD19-03548
| BLD-Framing/Rough-in | 4/30/2020 | 5/1/2020 | 5/1/2020 11:28:28 AM | A | PASS |
|
|
Les Phone #: ###-####
|
BLD20-00918
| BLD-Final | 4/30/2020 | 5/1/2020 | 5/1/2020 11:27:51 AM | A | PASS |
|
|
Please and thank you. Have a great weekend!! Phone #: ###-#### Inspection requested via web by Candyce Moss
|
BLD20-00918
| DOC - Permit Finaled | 5/1/2020 | 5/1/2020 | 5/1/2020 11:27:41 AM | P | PASS |
|
|
|
BLD19-03001
| BLD-Energy code compliance | 4/30/2020 | 5/1/2020 | 5/1/2020 11:27:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laz Ponce
|