Inspections for the day of: Wednesday, May 10, 2006.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy James
TitleMEC-COM/RES INSPECTOR
Phone #794-9461
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC06-01487 Rough-in5/10/20065/10/20065/11/2006 9:21:27 AMPFAIL
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
see permit 06-1482 for notes
MEC06-01487 Pressure Test5/10/20065/10/20065/11/2006 9:20:56 AMPPASS
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
MEC06-01483 Pressure Test5/10/20065/10/20065/11/2006 9:20:41 AMPPASS
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
MEC06-01483 Rough-in5/10/20065/10/20065/11/2006 9:20:28 AMPFAIL
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
see permit 06-1482 for notes
MEC06-01482 Pressure Test5/10/20065/10/20065/11/2006 9:19:46 AMPPASS
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
MEC06-01482 Rough-in5/10/20065/10/20065/11/2006 9:19:25 AMPFAIL
carl; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
hang flex duct per installation intructions, b-vent in attic only, need access to platform with 3 furnaces, no rough inspection before approval given for cover
MEC06-01485 Pressure Test5/10/20065/10/20065/10/2006 3:25:40 PMPFAIL
andrea ###-####
gas sizing to south/east unit needs to be verified
MEC06-01485 Rough-in5/10/20065/10/20065/10/2006 3:25:04 PMPFAIL
andrea ###-####
c/n posted
MEC06-01461 Rough-in5/10/20065/10/20065/10/2006 2:57:44 PMPPASS
MEC06-01461 Final5/10/20065/10/20065/10/2006 2:57:15 PMPFAIL
rick -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
not ready for final
MEC06-01313 Rough-in5/9/20065/10/20065/10/2006 1:33:37 PMAFAIL
call Rob at ###-#### for access if you need. Thanks, Andrea.; Phone #: ###-#### Internet Inspection Request from: Andrea Creek
need 1" clearance to insulation from fire box, need installation instructions to verify clearance at front flange
MEC06-00726 Final5/9/20065/10/20065/10/2006 1:01:09 PMAFAIL
Thank you Cassi Sickels!; Phone #: ###-#### x201 Internet Inspection Request from: Sickles Cassi
water to be set, air balance for hood, extend flue at rtu on roof, firewrap need steel bands, makeup air to pizza oven
MEC06-00636 Final5/10/20065/10/20065/10/2006 12:59:35 PMPCANC
unable to get to roof access, setting tile on floor
MEC06-01470 Rough-in5/9/20065/10/20065/10/2006 12:00:21 PMAFAIL
Internet Inspection Request from: Shelley Baisch
framing not complete at fireplace
MEC06-01462 Pressure Test5/9/20065/10/20065/10/2006 11:41:19 AMAPASS
Phone #: ###-#### Internet Inspection Request from: misty evans
MEC06-01462 Rough-in5/9/20065/10/20065/10/2006 11:40:42 AMAPASS
Phone #: ###-#### Internet Inspection Request from: misty evans
MEC06-00268 Final5/9/20065/10/20065/10/2006 10:30:46 AMAPASS
bonnie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
MEC06-01476 Rough-in5/9/20065/10/20065/10/2006 10:29:05 AMAFAIL
rob ###-####
no access to attic to inspect ducts and no plans on site
MEC06-00636 MEC-Aging Inspection5/10/20065/10/20065/10/2006 10:04:03 AM CANC
MEC05-04085 MEC-Aging Inspection5/10/20065/10/20065/10/2006 9:44:03 AM PASS
MEC05-04085 Mec-Request for Extension5/10/20065/10/20065/10/2006 9:43:53 AMAPASS
waiting for roof to be completed