Inspections for the day of: Tuesday, May 10, 2016.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01409 Rough-In Permanent Service5/10/20165/10/20165/10/2016 1:30:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson rough-in ok cover p/s u/g n ok
ELE16-01158 Rough-In Permanent Service5/10/20165/10/20165/10/2016 1:01:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder rough-in ok cover p/s u/g n ok
ELE13-02096 ELE-Aging Inspection5/10/20165/10/20165/10/2016 12:15:07 PM PASS
discussed with brad he will look into
ELE16-01474 Temporary Service5/10/20165/10/20165/10/2016 11:56:16 AMPPASS
re-inspect Phone #: ###-#### Inspection requested via web by Greg Idsinga correction fixed t/s u/g n ok
ELE14-02660 Final5/6/20165/10/20165/10/2016 10:33:18 AMAPASS
Homeowner will be home Phone #: ###-#### Inspection requested via web by John Harvey
office final only ok
ELE15-00402 Final5/6/20165/10/20165/10/2016 10:32:34 AMAFAIL
Homeowner will be home Phone #: ###-#### Inspection requested via web by John Harvey
334.30 type NM cable shall be supported with 12" of a box
210.8 portions of unfinished basements shall have GFCI protection
ALL IN DN MECHANICAL ROOM
ELE14-00776 Final5/9/20165/10/20165/10/2016 10:30:35 AMAFAIL
Homeowners will be on site Phone #: ###-#### Inspection requested via web by John Harvey
210.8 bathrooms shall have GFCI protection(up bath)
314.20 boxes recessed more then 1/4" shall have a listed extender
406.5 receptacles shall be rigidly mounted(through out house)
ELE16-01484 Electrical Rough-In5/9/20165/10/20165/10/2016 9:57:03 AMAPASS
Call for access Phone #: ###-#### Inspection requested via web by John VanZandt
Detached storage/office ok cover EC will move existing panel to flush with surface once sheetrock is installed
ELE16-01197 Electrical Rough-In5/9/20165/10/20165/10/2016 9:43:05 AMAPASS
This is for the floor heat, to cover. If you have any questions, please call Mike at 412.7848. Thank You! Phone #: ###-#### Inspection requested via web by Clay Morgan
Master bath floor heat ok cover
ELE16-00545 Final5/9/20165/10/20165/10/2016 9:22:29 AMAFAIL
Phone #: ###-#### Inspection requested via web by Lars Johnson
422.31 permanently installed appliances shall have means of lockout
210.8 (6) receptacles serving countertop shall have GFCI protection
ELE16-01474 Temporary Service5/9/20165/10/20165/10/2016 8:59:05 AMAFAIL
Phone #: ###-#### Inspection requested via web by Greg Idsinga grounding electrode system required