ELE18-01751
| Conference | 5/10/2018 | 5/10/2018 | 5/10/2018 3:26:33 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Brad Rowen Brad is married to Hilda Fernandes daughter and resides at residence. Discussed 2 basement bathroom remodel. 20 amp dedicated circuit to receptacles, location, tamper resistant, NM secure and support, ampacity for 20 amp, bath fan located in shower owner to check instruction to check if allowed. possible path to get circuit to bathroom receptacles. Open wiring behind mechanical door to be installed in a box. Most frequently asked question hand out given.
|
ELE18-01049
| Final | 5/10/2018 | 5/10/2018 | 5/10/2018 2:10:45 PM | P | PART |
|
|
Except cubicles Phone #: ###-#### Inspection requested via web by Ron Zimmerman Corrections not complete. EMT above trusses existing from original install and no wiring added. OK to remain. 300.4(E)- MC cables shall not run over trusses in shallow grooves. Only exception is for IMC and RMC can be installed with in 1 1/2" of lowest part of roof decking. Contractor will either move MC cables or protect with IMC or heavier shield. All located above trusses. Will check on final. Signed card TCO
|
ELE18-01748
| Rough-In Permanent Service | 5/9/2018 | 5/10/2018 | 5/10/2018 12:44:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder No service work done... upstairs remodel rough in ok cover.
|
ELE18-00130
| Electrical Rough-In | 5/10/2018 | 5/10/2018 | 5/10/2018 11:16:06 AM | P | PASS |
|
|
We need an inspection on the upper level bathroom electric floor heat! Phone #: ###-#### Inspection requested via web by Steven Meredith Completed both at am inspection
|
ELE18-01359
| Electrical Rough-In | 5/9/2018 | 5/10/2018 | 5/10/2018 11:11:08 AM | A | PASS |
|
|
Job Foreman : Jay Karel Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Listing confirmed rough in ok
|
ELE18-00130
| Electrical Rough-In | 5/10/2018 | 5/10/2018 | 5/10/2018 10:51:56 AM | A | PASS |
|
|
We need an inspection on the basement bathroom electric floor heat! Phone #: ###-#### Inspection requested via web by Steven Meredith BAsement and upstair bath floor heat rough in ok cover.
|
ELE17-01337
| Electrical Rough-In | 5/9/2018 | 5/10/2018 | 5/10/2018 10:27:23 AM | A | PASS |
|
|
We are requesting an underground light pole inspection on the East side of the project. Our contact is Rick Badley @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate South east light pole base and underground rough in ok cover
|
ELE18-01295
| Electrical Rough-In | 5/9/2018 | 5/10/2018 | 5/10/2018 9:52:02 AM | A | PASS |
|
|
r/i for East side // Jose Phone #: ###-#### East furniture ok to occupy.
|
ELE18-01291
| Rough-In Permanent Service | 5/9/2018 | 5/10/2018 | 5/10/2018 9:25:00 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon Rough in ok cover p/s u/g n ok
|