Inspections for the day of: Friday, May 11, 2001.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTony Young
TitleBLD-COM/RES INSPECTOR
Phone #794-9462
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-00896 BLD-Foundation5/10/20015/11/20015/11/2001 12:00:00 AMANR
###-#### Tim
BLD01-01236 BLD-Footing5/10/20015/11/20015/11/2001 12:00:00 AMAPART
###-####
wip, verbal corrections 5/11/2001 10:22:03 AM
BLD00-03409 BLD-Framing/Rough-in5/10/20015/11/20015/11/2001 12:00:00 AMAPART
shear wall phil ###-####
exterior shear only ok 5/11/2001 11:15:43 AM
BLD01-00625 BLD-Framing/Rough-in5/10/20015/11/20015/11/2001 12:00:00 AMAFAIL
todd ###-####
need to put in fire blocks in the party wall/ property line fire wall and increase nailing per plan 5/11/2001 9:46:34 AM
BLD01-01079 BLD-Foundation5/10/20015/11/20015/11/2001 12:00:00 AMAPART
ryan ###-####
BLD01-01236 BLD-Conference5/11/20015/11/20015/11/2001 12:00:00 AMAPART
Added by Inspector: 415 On 5/11/2001 10:21:33 AM conf. on project, NOTE: Mike is verbaly confrontational, the last project on elmer st. did not go well and was charged a reinspection fee for numerous framing inspections. conf. on following the plans, calling for inspections, etc.
MEC01-00859 Final5/11/20015/11/20015/11/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 05/11/2001 at 11:05:22. Contact: ###-####.
BLD01-00626 BLD-Framing/Rough-in5/11/20015/11/20015/11/2001 12:00:00 AMPPART
###-####
int. party/ fire wall ok to stand, wall and attic truss, some verbal corrections 5/11/2001 2:54:42 PM
BLD01-00672 BLD-Framing/Rough-in5/11/20015/11/20015/11/2001 12:00:00 AMPPART
Added by Inspector: 415 On 5/11/2001 2:37:50 PM ext. shear ok
BLD01-00672 BLD-Conference5/11/20015/11/20015/11/2001 12:00:00 AMPPASS
conf. on shear 5/11/2001 2:45:30 PM
BLD01-00625 BLD-Wall cover5/11/20015/11/20015/11/2001 12:00:00 AMPPART
Added by Inspector: 415 On 5/11/2001 2:45:02 PM int prop. line fire wall ok
MEC00-04368 Final5/11/20015/11/20015/11/2001 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 05/11/2001 at 08:55:19. Contact: ###-####.c/n posted, gas test, fans 5/11/2001 1:08:25 PM