Inspections for the day of: Wednesday, May 11, 2005.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-00146 ELE-Aging Inspection5/11/20055/11/20055/11/2005 12:00:00 AM PASS
ELE05-00448 ELE-Aging Inspection5/11/20055/11/20055/11/2005 12:00:00 AM PASS
ok 5/11/2005 2:27:15 PM
ELE05-01592 Permanent Service5/10/20055/11/20055/11/2005 12:00:00 AMAPASS
service upgrade Internet Inspection Request from: Andy Rose p/s o/h rec. ok 5/11/2005 9:15:58 AM
ELE05-01234 Permanent Service5/10/20055/11/20055/11/2005 12:00:00 AMACANC
Scheduled by a contractor via Hello! on 5/10/2005 at 4:17:13 PM. Contact: ###-####. called contractor needs correct address 6232 meeker 5/11/2005 11:33:43 AM
ELE05-01634 Electrical Rough-In5/11/20055/11/20055/11/2005 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 5/11/2005 at 6:53:53 AM. Contact: ###-####. cor. and do not cover posted talked with owner, 314.16 box fill, 250.148 pigtail all equip grds at jboxes, staple within 8 or 12 inches of plastic and metal boxes, 300.14 6" free length, splices not made up tight, seal all KOs, and replace plastic boxes with unused KOs note 432 made note of box fil, grd boxes, and 11/4 during conference on 05-09-05 5/11/2005 4:26:01 PM
ELE05-01355 Final5/10/20055/11/20055/11/2005 12:00:00 AMPFAIL
tony; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cor. posted spray booth shall be field evaluated, power disconnected, and shall start process of field evaluation within 48 hours met owner 5/11/2005 4:24:44 PM
ELE05-01645 Temporary Service5/11/20055/11/20055/11/2005 12:00:00 AMPPASS
###-#### karen t/s o/h new ok 5/11/2005 12:59:40 PM
ELE05-01643 Permanent Service5/11/20055/11/20055/11/2005 12:00:00 AMPNH
100 amp service upgrade Internet Inspection Request from: Andy Rose notice posted called 5/11/2005 1:41:25 PM
ELE04-02132 ELE-Request for Extension5/11/20055/11/20055/11/2005 12:00:00 AMPPASS
Carl will start working on this job when the weather clears ###-####. ok 5/11/2005 12:28:27 PM
ELE05-00867 Final5/11/20055/11/20055/11/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 5/11/2005 at 10:54:59 AM. Contact: ###-####. ok signed inspection record no occupancy card at site final ok 5/11/2005 3:31:54 PM
ELE05-01650 Permanent Service5/11/20055/11/20055/11/2005 12:00:00 AMPPASS
mitch ###-#### p/s o/ 5/11/2005 2:50:43 PM rec. for meter u/g r/i ok also 5/11/2005 2:51:03 PM
ELE05-01234 Permanent Service5/11/20055/11/20055/11/2005 12:00:00 AMPPASS
per jack frank will do today p/s u/g new for meter 5/11/2005 12:28:19 PM