BLD06-01169
| BLD-Final | 5/11/2006 | 5/11/2006 | 5/11/2006 4:11:25 PM | P | NR |
|
|
gary; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs elec. final.
|
BLD05-02752
| BLD-Framing/Rough-in | 5/11/2006 | 5/11/2006 | 5/11/2006 3:23:51 PM | P | NR |
|
|
todd; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. East exterior wall and south exterior wall has been insulated. ok to cover. Partition walls not complete.
|
BLD06-00007
| BLD-Footing | 5/11/2006 | 5/11/2006 | 5/11/2006 3:03:25 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 5/11/2006 at 7:35:58 AM. Contact: ###-####. Extension of exsiting column pad footing.
|
MIS06-00107
| BLD-Conference | 5/10/2006 | 5/11/2006 | 5/11/2006 2:51:35 PM | P | DONE |
|
|
please call a half hour prior to inspection at ###-#### sonia
|
BLD05-02671
| BLD-Framing/Rough-in | 5/10/2006 | 5/11/2006 | 5/11/2006 2:35:54 PM | P | PART |
|
|
christi; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Compressor room not complete. rogg framing and mezz. ok. Noted 2hr seperation wall, Need wall assembly from architect, Putty pads required on steel boxes, Also need verification of UL listing on installed door frames, no tags present. Also need UL listings on penetrations for fire caulking from elec. All pending mech ri. Ok to one side walls.
|
BLD05-03384
| BLD-Framing/Rough-in | 5/10/2006 | 5/11/2006 | 5/11/2006 1:57:06 PM | P | PASS |
|
|
late pm??jeff; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD06-00266
| BLD-Energy code compliance | 5/11/2006 | 5/11/2006 | 5/11/2006 1:35:13 PM | P | PASS |
|
|
ned ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD06-00266
| BLD-Framing/Rough-in | 5/11/2006 | 5/11/2006 | 5/11/2006 1:34:59 PM | P | PASS |
|
|
ned ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. All framing issues have been resolved.
|
BLD05-01459
| BLD-Aging Inspection | 5/11/2006 | 5/11/2006 | 5/11/2006 11:45:55 AM | | NR |
|
|
|
MIS06-00026
| MIS-Aging Inspection | 5/11/2006 | 5/11/2006 | 5/11/2006 11:45:42 AM | | NR |
|
|
Mobile home has been moved. Block and tie not yet complete. No occupants.
|
MIS05-00067
| MIS-Aging Inspection | 5/11/2006 | 5/11/2006 | 5/11/2006 11:02:58 AM | | CANC |
|
|
|
MIS05-00067
| DOC - Permit Expired | 5/11/2006 | 5/11/2006 | 5/11/2006 11:02:49 AM | A | DONE |
|
|
stairway and handrails installed. No occupants.
|
BLD06-00984
| BLD-Foundation | 5/10/2006 | 5/11/2006 | 5/11/2006 9:35:40 AM | A | PART |
|
|
bob Note: wall foundation - late morning 11:30 is possible; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. wip. All reinforcement tied. Placing forms.
|
BLD06-00894
| BLD-Foundation | 5/10/2006 | 5/11/2006 | 5/11/2006 9:10:12 AM | A | PASS |
|
|
josh Note: wall foundation; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-01431
| BLD-Aging Inspection | 5/11/2006 | 5/11/2006 | 5/11/2006 8:22:16 AM | | CANC |
|
|
|
BLD05-01431
| DOC - Permit Finaled | 5/11/2006 | 5/11/2006 | 5/11/2006 8:22:08 AM | A | PASS |
|
|
|