ELE07-01719
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 3:32:04 PM | P | PASS |
|
|
u/g ok to cover from house to garage only
|
ELE07-01634
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 3:30:22 PM | P | PASS |
|
|
under ground conduit Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g ok to cover house to garage
|
ELE07-01465
| Electrical Rough-In | 5/10/2007 | 5/11/2007 | 5/11/2007 3:23:08 PM | A | FAIL |
|
|
Underground & Pool Grid bonding inspection. Please call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson called, left corr notice, nec 680.26(B) news breif, rebar shall have minimum 12" squares and be tied at each cross, called contr to verify split bolt listed for rebar and for being poured in concrete
|
ELE07-01423
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 2:57:48 PM | P | PASS |
|
|
under ground conduit Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g ok to cover house to garage
|
ELE07-01384
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 2:26:31 PM | P | PASS |
|
|
underground conduit Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g house to garage ok to cover
|
ELE07-01307
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 1:59:30 PM | P | PASS |
|
|
under ground conduit Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g house to garage ok to cover
|
ELE07-01108
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 1:29:28 PM | P | PASS |
|
|
under ground conduit Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g house to garage ok to cover
|
ELE07-01087
| Conference | 5/10/2007 | 5/11/2007 | 5/11/2007 12:47:48 PM | P | DONE |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met owner, looked at service, changing from o/h to u/g. New service was put on about 3 years ago, so owner mainly needs to just switch gec over to new service an split up branch circuits.
|
ELE07-01624
| Electrical Rough-In | 5/11/2007 | 5/11/2007 | 5/11/2007 10:43:26 AM | P | PASS |
|
|
Carl ###-#### concrete encased gec ok to pour, ground ring continuous in all footing
|
ELE07-01692
| Permanent Service | 5/11/2007 | 5/11/2007 | 5/11/2007 10:09:43 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Jim Williams p/s, exst meter base, n, ok
|
ELE07-01690
| Electrical Rough-In | 5/10/2007 | 5/11/2007 | 5/11/2007 9:08:59 AM | A | FAIL |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Darla Downs called, left corr notice nec 300.4(A) & (D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members
|
ELE07-00834
| Electrical Rough-In | 5/10/2007 | 5/11/2007 | 5/11/2007 7:58:11 AM | A | FAIL |
|
|
trench inspection in planter beds Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called, left corr notice, nec 300.5 raceways shall be minimum 18" from top of raceway to finished surface
|