ELE09-00231
| ELE-Aging Inspection | 5/12/2009 | 5/12/2009 | 5/13/2009 2:40:14 PM | | DONE |
|
|
looked at signs, see final, no esc this project
|
ELE09-00814
| Conference | 5/12/2009 | 5/12/2009 | 5/12/2009 4:00:29 PM | P | DONE |
|
|
Russ Phone #: ###-#### met contractor, told that if they sleeve broken conduit, that material shall be listed by nationally recognized testing laboratory, looks like could run new feeder for about same effort, rather than get into concrete encased duct bank for repairs, no esc this project
|
ESC09-00169
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:32:06 PM | P | FAIL |
|
|
see correction posted 5/11/09
|
ESC08-00588
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:30:11 PM | P | PASS |
|
|
looked ok, see site final
|
ESC08-00588
| Site Final | 5/12/2009 | 5/12/2009 | 5/12/2009 3:30:01 PM | P | PASS |
|
|
looked ok, ok to final
|
ESC08-00623
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:27:54 PM | P | PASS |
|
|
looked ok, see site final
|
ESC08-00623
| Site Final | 5/12/2009 | 5/12/2009 | 5/12/2009 3:27:38 PM | P | PASS |
|
|
ok to final
|
ESC08-00859
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:25:40 PM | P | PASS |
|
|
looked ok
|
ESC08-01045
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:13:19 PM | P | PASS |
|
|
looked ok
|
ESC06-01600
| Aging Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:10:55 PM | | PASS |
|
|
looked ok, no sign or activity, see site final
|
ESC06-01600
| Site Final | 5/12/2009 | 5/12/2009 | 5/12/2009 3:10:38 PM | P | PASS |
|
|
looked ok, no activity, ok to final
|
ESC09-00202
| General Inspection | 5/12/2009 | 5/12/2009 | 5/12/2009 3:08:54 PM | P | PASS |
|
|
looked ok
|
ELE09-00812
| Conference | 5/12/2009 | 5/12/2009 | 5/12/2009 2:32:58 PM | P | DONE |
|
|
Robert ###-#### talked about service and service disconnect for removing service meter from house and serving from garage, no esc this project
|
ELE09-00801
| Electrical Rough-In | 5/12/2009 | 5/12/2009 | 5/12/2009 1:58:56 PM | P | CANC |
|
|
Russ Phone #: ###-#### owner not present, told builder that owner must be there to review corrections and that owner has to call for inspection, no esc this project
|
ELE09-00686
| Final | 5/12/2009 | 5/12/2009 | 5/12/2009 12:59:39 PM | P | PASS |
|
|
Calvin Phone #: ###-#### ok to final, no esc this project
|
ELE09-00794
| Electrical Rough-In | 5/8/2009 | 5/12/2009 | 5/12/2009 10:48:36 AM | A | PASS |
|
|
Please final this when you are done. Onsite see Gordon, or Suzanne in the kitchen. James @ ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok, no esc this project
|
ELE09-00794
| Final | 5/12/2009 | 5/12/2009 | 5/12/2009 10:21:21 AM | A | PASS |
|
|
Please final this when you are done. Onsite see Gordon, or Suzanne in the kitchen. James @ ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final, no esc this project
|
ELE08-03211
| Final | 5/11/2009 | 5/12/2009 | 5/12/2009 10:19:09 AM | A | PASS |
|
|
Dave Phone #: ###-#### corrections made, ok to final
|
ELE09-00301
| Final | 5/11/2009 | 5/12/2009 | 5/12/2009 9:46:42 AM | A | PASS |
|
|
terry Phone #: ###-#### corrections made, ok to final
|
ELE09-00809
| Final | 5/11/2009 | 5/12/2009 | 5/12/2009 9:18:59 AM | A | PASS |
|
|
Jonathan Phone #: ###-#### Please call 15 min before going out, met owner, told to add gfci protection for garage, fix gfci for house, provide labelling for all panels, no esc this project
|
ELE09-00676
| Electrical Rough-In | 5/11/2009 | 5/12/2009 | 5/12/2009 8:45:59 AM | A | PASS |
|
|
Jared- call 30 misn prior to going Phone #: ###-#### ok to cover u/g to spa, no esc this project
|
ELE09-00376
| Final | 5/11/2009 | 5/12/2009 | 5/12/2009 8:19:45 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 5/11/2009 at 9:06:25 AM. Contact: ###-####. called, left correction notice, NEC 250.94 shall provide intersystem bond bar, 406.4 receptacles shall be securely fastened -garage, family room,media room, 110.3(B) listed equipment shall be installed per installation instructions- power for dining room receptacles, BCC all work shall be completed-back receptacle and light
|