Inspections for the day of: Tuesday, May 12, 2009.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00231 ELE-Aging Inspection5/12/20095/12/20095/13/2009 2:40:14 PM DONE
looked at signs, see final, no esc this project
ELE09-00814 Conference5/12/20095/12/20095/12/2009 4:00:29 PMPDONE
Russ Phone #: ###-#### met contractor, told that if they sleeve broken conduit, that material shall be listed by nationally recognized testing laboratory, looks like could run new feeder for about same effort, rather than get into concrete encased duct bank for repairs, no esc this project
ESC09-00169 General Inspection5/12/20095/12/20095/12/2009 3:32:06 PMPFAIL
see correction posted 5/11/09
ESC08-00588 General Inspection5/12/20095/12/20095/12/2009 3:30:11 PMPPASS
looked ok, see site final
ESC08-00588 Site Final5/12/20095/12/20095/12/2009 3:30:01 PMPPASS
looked ok, ok to final
ESC08-00623 General Inspection5/12/20095/12/20095/12/2009 3:27:54 PMPPASS
looked ok, see site final
ESC08-00623 Site Final5/12/20095/12/20095/12/2009 3:27:38 PMPPASS
ok to final
ESC08-00859 General Inspection5/12/20095/12/20095/12/2009 3:25:40 PMPPASS
looked ok
ESC08-01045 General Inspection5/12/20095/12/20095/12/2009 3:13:19 PMPPASS
looked ok
ESC06-01600 Aging Inspection5/12/20095/12/20095/12/2009 3:10:55 PM PASS
looked ok, no sign or activity, see site final
ESC06-01600 Site Final5/12/20095/12/20095/12/2009 3:10:38 PMPPASS
looked ok, no activity, ok to final
ESC09-00202 General Inspection5/12/20095/12/20095/12/2009 3:08:54 PMPPASS
looked ok
ELE09-00812 Conference5/12/20095/12/20095/12/2009 2:32:58 PMPDONE
Robert ###-#### talked about service and service disconnect for removing service meter from house and serving from garage, no esc this project
ELE09-00801 Electrical Rough-In5/12/20095/12/20095/12/2009 1:58:56 PMPCANC
Russ Phone #: ###-#### owner not present, told builder that owner must be there to review corrections and that owner has to call for inspection, no esc this project
ELE09-00686 Final5/12/20095/12/20095/12/2009 12:59:39 PMPPASS
Calvin Phone #: ###-#### ok to final, no esc this project
ELE09-00794 Electrical Rough-In5/8/20095/12/20095/12/2009 10:48:36 AMAPASS
Please final this when you are done. Onsite see Gordon, or Suzanne in the kitchen. James @ ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok, no esc this project
ELE09-00794 Final5/12/20095/12/20095/12/2009 10:21:21 AMAPASS
Please final this when you are done. Onsite see Gordon, or Suzanne in the kitchen. James @ ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final, no esc this project
ELE08-03211 Final5/11/20095/12/20095/12/2009 10:19:09 AMAPASS
Dave Phone #: ###-#### corrections made, ok to final
ELE09-00301 Final5/11/20095/12/20095/12/2009 9:46:42 AMAPASS
terry Phone #: ###-#### corrections made, ok to final
ELE09-00809 Final5/11/20095/12/20095/12/2009 9:18:59 AMAPASS
Jonathan Phone #: ###-#### Please call 15 min before going out, met owner, told to add gfci protection for garage, fix gfci for house, provide labelling for all panels, no esc this project
ELE09-00676 Electrical Rough-In5/11/20095/12/20095/12/2009 8:45:59 AMAPASS
Jared- call 30 misn prior to going Phone #: ###-#### ok to cover u/g to spa, no esc this project
ELE09-00376 Final5/11/20095/12/20095/12/2009 8:19:45 AMAFAIL
Scheduled by a contractor via Hello! on 5/11/2009 at 9:06:25 AM. Contact: ###-####. called, left correction notice, NEC 250.94 shall provide intersystem bond bar, 406.4 receptacles shall be securely fastened -garage, family room,media room, 110.3(B) listed equipment shall be installed per installation instructions- power for dining room receptacles, BCC all work shall be completed-back receptacle and light