ELE08-00562
| ELE-Aging Inspection | 5/12/2010 | 5/12/2010 | 5/18/2010 4:48:02 AM | | DONE |
|
|
see final
|
ELE08-00534
| ELE-Aging Inspection | 5/12/2010 | 5/12/2010 | 5/18/2010 4:45:51 AM | | DONE |
|
|
see doc expire
|
ELE04-03346
| ELE-Aging Inspection | 5/12/2010 | 5/12/2010 | 5/14/2010 12:04:18 PM | | DONE |
|
|
see doc expire
|
ELE04-03102
| ELE-Aging Inspection | 5/12/2010 | 5/12/2010 | 5/14/2010 11:56:00 AM | | DONE |
|
|
see doc expire
|
ELE10-01007
| Conference | 5/10/2010 | 5/12/2010 | 5/12/2010 3:55:56 PM | P | DONE |
|
|
Dan Osler-Around 3:30 if possible please Phone #: ###-#### talked about service change and grounding
|
ELE10-00988
| Rough-In Permanent Service | 5/11/2010 | 5/12/2010 | 5/12/2010 3:10:53 PM | P | PASS |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-#### ric ok, p/s u/g n ok
|
ELE10-01041
| Rough-In Permanent Service | 5/11/2010 | 5/12/2010 | 5/12/2010 2:14:25 PM | P | FAIL |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called, left correction notice, NEC 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(E)(1) shall provide receptacle at rear of dwelling, 334.23 shall protect cables at attic access- up and down, Note corrections shall be made within 5 working days or further action will be taken
|
ELE10-01048
| Electrical Rough-In | 5/12/2010 | 5/12/2010 | 5/12/2010 1:23:44 PM | P | PASS |
|
|
Please call Clark(contractor) Prior to arrival for access. ###-####. Thank you. Inspection requested from web by: Lee Braithwait Phone #: ###-#### ric ok
|
ELE10-00968
| Final | 5/11/2010 | 5/12/2010 | 5/12/2010 12:55:12 PM | P | PASS |
|
|
Final on Permenant Service Inspection requested from web by: Randy Fletcher Phone #: ###-#### corrections made, ok to final
|
ELE10-00910
| Final | 5/11/2010 | 5/12/2010 | 5/12/2010 12:21:18 PM | P | PASS |
|
|
Lockbox is on the garage man-door Code is 1290, any questions please give Clay a call. Thank You. Inspection requested from web by: Clay Morgan Phone #: ###-#### ok to final
|
ELE10-01031
| Final | 5/11/2010 | 5/12/2010 | 5/12/2010 10:24:28 AM | A | CANC |
|
|
please call 30 min prior to meet you//Lloyd ###-#### (note: permit pulled after work done and building permit received perm. C of O). ok to final
|
ELE10-00146
| Final | 5/12/2010 | 5/12/2010 | 5/12/2010 10:18:12 AM | P | CANC |
|
|
Can you please call me before you head over there so I can meet you there if possible? Thank You, Mark Inspection requested from web by: Mark Hennequin Phone #: ###-#### Inspection cancelled from web by: Barbara Stitt
|
ELE10-01026
| Permanent Service | 5/11/2010 | 5/12/2010 | 5/12/2010 9:54:12 AM | A | PASS |
|
|
100amp service upgrade, any questions call Jake @ ###-#### Inspection requested from web by: Andy Rose Phone #: ###-#### p/s o/h rec ok
|
ELE10-01038
| Temporary Service | 5/11/2010 | 5/12/2010 | 5/12/2010 9:15:10 AM | A | FAIL |
|
|
THANKS Inspection requested from web by: Bob Glenn Phone #: ###-#### called to post address, fix 250v receptacle and provide work clearance
|
ELE10-01037
| Temporary Service | 5/11/2010 | 5/12/2010 | 5/12/2010 9:00:14 AM | A | PASS |
|
|
THANKS Inspection requested from web by: Bob Glenn Phone #: ###-#### called to post address t/s u/g n ok
|
ELE10-01042
| Final | 5/11/2010 | 5/12/2010 | 5/12/2010 8:34:25 AM | A | CANC |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### wrong type request, see rip
|
ELE10-01042
| Rough-In Permanent Service | 5/12/2010 | 5/12/2010 | 5/12/2010 8:33:56 AM | A | FAIL |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called contractor, told to fix NEC 334.23, attic access and 300.4 nailplates, then to call back in
|
ELE10-00680
| Electrical Rough-In | 5/11/2010 | 5/12/2010 | 5/12/2010 8:03:39 AM | A | PASS |
|
|
underground Inspection requested from web by: Mark Sessions Phone #: ###-#### ok to cover u/g north and east of building
|