Inspections for the day of: Thursday, May 12, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01988 ELE-Aging Inspection5/12/20165/12/20165/20/2016 7:27:05 AM CANC
too busy
ELE12-01914 ELE-Aging Inspection5/12/20165/12/20165/19/2016 8:26:12 AM CANC
too busy
ELE16-01288 Permanent Service5/12/20165/12/20165/12/2016 2:41:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Thomas Jenkins
EC and GC will build a dividing wall between gas and electrical meter for final p/s u/g rec ok one meter
ELE16-00974 Electrical Rough-In5/11/20165/12/20165/12/2016 1:51:05 PMPCANC
Bob Phone #: ###-#### needed conference
ELE16-00974 Conference5/12/20165/12/20165/12/2016 1:50:39 PMPDONE
Bob Phone #: ###-####
Discussed wiring and code requirements for laundry and bath addition
ELE15-03552 Final5/12/20165/12/20165/12/2016 1:18:58 PMPFAIL
We are requesting a final inspection for this project for this afternoon. Our contact is Trent @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
314.20 recessed boxes behind tile shall have a listed extender
210.12 AFCI protection required (master)
210.52(C) wall counter top spacing shall have a receptacle located with 24" of counter edge and not less then 48" apart
408.4 Field indentification for panel board
422.31 Permanently installed appliances shall have means of lockout
334.12 Type NM cable shall not be used when subject to physical damage(garage)
334.30 Type NM cable shall be supported within 12" of a box or connector
406.4 Tamper resistant receptacles required(garage)
406.5 Receptacles shall be rigidly mounted(through out house)
ELE15-02776 Final5/12/20165/12/20165/12/2016 12:14:28 PMPFAIL
Mike Phone #: ###-####
406.4(5) tamper resistant receptacles required(GFCI in bath)
410.10 lights located within shower areas shall be listed and shall have a totally enclosed lamp
MIS16-00144 ELE-Final5/11/20165/12/20165/12/2016 12:00:44 PMPPASS
Chantell/// ###-####---MIS created so inspections can be done for Electrical and Plumbing sign-off for permanent occupancy- per CDM
electrical final ok
ELE16-01318 Electrical Rough-In5/11/20165/12/20165/12/2016 10:41:22 AMAPASS
Underground for (3) LV pool lights Phone #: ###-#### Inspection requested via web by Lars Johnson
Underground for pool lights ok cover
ELE15-02952 Final5/11/20165/12/20165/12/2016 10:19:08 AMAPASS
I am going to Donnelly so might not be able to answer phone but should be good to go bath is finished- except for gas line to dryer- added a fan and timer in 2nd bath where gfci is located - have installed 6 new circuits to this area - check panel on kitchen side for breakers Phone #: ###-#### Inspection requested via web by dennis mcneely
both upstairs baths final ok
ELE16-01046 Electrical Rough-In5/11/20165/12/20165/12/2016 9:51:17 AMAPASS
Equipotential bonding plane, basketball sleeve bonding Phone #: ###-#### Inspection requested via web by Lars Johnson
Equipotential bonding around perimeter of pool ok cover
ELE15-04113 Electrical Rough-In5/11/20165/12/20165/12/2016 9:30:19 AMAPASS
Installing heat matt in concrete at 9:00 am Phone #: ###-#### Inspection requested via web by John VanZandt drive way heated mats ok cover(cold leads shall be installed in conduit to juction box)
ESC16-00003 Site Final5/12/20165/12/20165/12/2016 8:51:33 AMPPASS
site final ok
ELE16-00692 Final5/11/20165/12/20165/12/2016 8:50:13 AMAPASS
Garden code 1280 Phone #: ###-#### Inspection requested via web by TOM BICANDI corrections fixed final ok