ELE12-01988
| ELE-Aging Inspection | 5/12/2016 | 5/12/2016 | 5/20/2016 7:27:05 AM | | CANC |
|
|
too busy
|
ELE12-01914
| ELE-Aging Inspection | 5/12/2016 | 5/12/2016 | 5/19/2016 8:26:12 AM | | CANC |
|
|
too busy
|
ELE16-01288
| Permanent Service | 5/12/2016 | 5/12/2016 | 5/12/2016 2:41:50 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins EC and GC will build a dividing wall between gas and electrical meter for final p/s u/g rec ok one meter
|
ELE16-00974
| Electrical Rough-In | 5/11/2016 | 5/12/2016 | 5/12/2016 1:51:05 PM | P | CANC |
|
|
Bob Phone #: ###-#### needed conference
|
ELE16-00974
| Conference | 5/12/2016 | 5/12/2016 | 5/12/2016 1:50:39 PM | P | DONE |
|
|
Bob Phone #: ###-#### Discussed wiring and code requirements for laundry and bath addition
|
ELE15-03552
| Final | 5/12/2016 | 5/12/2016 | 5/12/2016 1:18:58 PM | P | FAIL |
|
|
We are requesting a final inspection for this project for this afternoon. Our contact is Trent @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate 314.20 recessed boxes behind tile shall have a listed extender 210.12 AFCI protection required (master) 210.52(C) wall counter top spacing shall have a receptacle located with 24" of counter edge and not less then 48" apart 408.4 Field indentification for panel board 422.31 Permanently installed appliances shall have means of lockout 334.12 Type NM cable shall not be used when subject to physical damage(garage) 334.30 Type NM cable shall be supported within 12" of a box or connector 406.4 Tamper resistant receptacles required(garage) 406.5 Receptacles shall be rigidly mounted(through out house)
|
ELE15-02776
| Final | 5/12/2016 | 5/12/2016 | 5/12/2016 12:14:28 PM | P | FAIL |
|
|
Mike Phone #: ###-#### 406.4(5) tamper resistant receptacles required(GFCI in bath) 410.10 lights located within shower areas shall be listed and shall have a totally enclosed lamp
|
MIS16-00144
| ELE-Final | 5/11/2016 | 5/12/2016 | 5/12/2016 12:00:44 PM | P | PASS |
|
|
Chantell/// ###-####---MIS created so inspections can be done for Electrical and Plumbing sign-off for permanent occupancy- per CDM electrical final ok
|
ELE16-01318
| Electrical Rough-In | 5/11/2016 | 5/12/2016 | 5/12/2016 10:41:22 AM | A | PASS |
|
|
Underground for (3) LV pool lights Phone #: ###-#### Inspection requested via web by Lars Johnson Underground for pool lights ok cover
|
ELE15-02952
| Final | 5/11/2016 | 5/12/2016 | 5/12/2016 10:19:08 AM | A | PASS |
|
|
I am going to Donnelly so might not be able to answer phone but should be good to go bath is finished- except for gas line to dryer- added a fan and timer in 2nd bath where gfci is located - have installed 6 new circuits to this area - check panel on kitchen side for breakers Phone #: ###-#### Inspection requested via web by dennis mcneely both upstairs baths final ok
|
ELE16-01046
| Electrical Rough-In | 5/11/2016 | 5/12/2016 | 5/12/2016 9:51:17 AM | A | PASS |
|
|
Equipotential bonding plane, basketball sleeve bonding Phone #: ###-#### Inspection requested via web by Lars Johnson Equipotential bonding around perimeter of pool ok cover
|
ELE15-04113
| Electrical Rough-In | 5/11/2016 | 5/12/2016 | 5/12/2016 9:30:19 AM | A | PASS |
|
|
Installing heat matt in concrete at 9:00 am Phone #: ###-#### Inspection requested via web by John VanZandt drive way heated mats ok cover(cold leads shall be installed in conduit to juction box)
|
ESC16-00003
| Site Final | 5/12/2016 | 5/12/2016 | 5/12/2016 8:51:33 AM | P | PASS |
|
|
site final ok
|
ELE16-00692
| Final | 5/11/2016 | 5/12/2016 | 5/12/2016 8:50:13 AM | A | PASS |
|
|
Garden code 1280 Phone #: ###-#### Inspection requested via web by TOM BICANDI corrections fixed final ok
|