Inspections for the day of: Tuesday, May 12, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-01845 Final5/11/20205/12/20205/12/2020 3:30:04 PMPPASS
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
PLM20-01932 Water Heater Final5/11/20205/12/20205/12/2020 3:29:03 PMPPASS
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- w/h co ok
MEC20-00592 Final5/12/20205/12/20205/12/2020 2:31:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Sarah Small- final ok
MEC20-00592 Card not on site to sign5/12/20205/12/20205/12/2020 2:30:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Sarah Small- card not onsite ti sign
MEC20-01342 Rough-in5/12/20205/12/20205/12/2020 1:40:37 PMPPASS
fire/smoke damper angles ok- labeling on grid and access doors for fire/smoke dampers ok- exhaust termination on roof ok- insulation and registers ok- ok for ceiling tiles- pics sent via text for all items listed- call in final when ready
MEC20-01704 Rough-in5/12/20205/12/20205/12/2020 1:28:05 PMPPASS
call for access // Shannon Phone #: ###-####- R/I ok
MEC20-01704 Pressure Test5/12/20205/12/20205/12/2020 1:26:49 PMPPASS
call for access // Shannon Phone #: ###-####- 20lb gas pass whole system- tagged meter location
MEC20-01787 Final5/12/20205/12/20205/12/2020 11:56:28 AMAPASS
final ok- correction made- pic sent via text
MEC20-00278 Rough-in5/11/20205/12/20205/12/2020 11:23:47 AMAPART
Pool room please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- need clarificationpool heaters being installed are class 1-no cover til resolved on pool heater room- 2 bath rooms ok to cover- Justin will let me know
MIS20-00066 MEC-Conference5/12/20205/12/20205/12/2020 10:33:37 AMADONE
meet at 10 am- see Chad S notes
MEC19-05815 Final5/11/20205/12/20205/12/2020 9:46:06 AMAPASS
please call john prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- final ok- no card onsite to sign GC trailer locked up
MEC19-05815 Card not on site to sign5/12/20205/12/20205/12/2020 9:45:35 AMAPASS
please call john prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- GC trailer lock up not onsite- no card to sign
MEC20-00592 Final5/11/20205/12/20205/12/2020 9:20:03 AMAFAIL
Phone #: ###-#### Inspection requested via web by Sarah Small
1- mini split condenser needs locking caps on service ports
2- condenser needs secured to poly 3" supports
3- need to remove foil tape from b vent near unit heater and install trim ring around b vent and firecaulk
4- need to fire caulk gas line and (4) allthread penetrations in ceiling of garage

left notice front room window
MEC20-00878 Rough-in5/11/20205/12/20205/12/2020 8:37:11 AMAPASS
Tyler *screened* Phone #: ###-####- R/I ok- transfers will be cut in on final- need picture of range duct support at final homeowner will provide wants to get range hood spot on before securing into place
MEC19-04530 Mec-Aging Inspection5/12/20205/12/20205/12/2020 8:00:39 AM CANC
needs called in for inspection when ready- WIP
MEC19-04642 Mec-Aging Inspection5/12/20205/12/20205/12/2020 8:00:05 AM FAIL
permit no active since issued- needs called in for inspection- permit will expire next aging if no activity