ELE14-00952
| Permanent Service | 5/13/2014 | 5/13/2014 | 5/13/2014 3:51:37 PM | P | FAIL |
|
|
Web Robertson Phone #: ###-#### Due to modifications new code violations exist. 110.26- Minimum work platform 30" wide and 36" deep. 240.24(A)- Each circuit breaker that can be installed shall be below 6'7". 250.64(B)- Where exposed a #4 minimum copper grounding electrode conductor shall be installed where subject to physical damage. 250.56- Ground rods shall be installed a minimum of 6' apart. 230.24(A)- Service mast shall clear short overhang portion of roof by minimum of 18". Tried to contact owner 2 times. sounded like voicemail was available on 2nd call but not sure if operational .
|
ELE14-01220
| Electrical Rough-In | 5/13/2014 | 5/13/2014 | 5/13/2014 3:02:47 PM | P | PASS |
|
|
Go thru gate on side of house to back yard any questions pleas call shaun ###-#### thanks Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Garage addition to back of house garage. Rough in ok cover
|
ELE14-00952
| Final | 5/13/2014 | 5/13/2014 | 5/13/2014 2:09:02 PM | P | CANC |
|
|
Web Robertson Phone #: ###-#### Needed permenant service inspection.
|
ELE14-01210
| Permanent Service | 5/13/2014 | 5/13/2014 | 5/13/2014 1:44:28 PM | P | NH |
|
|
CONTACT: CODY CANNON Phone #: ###-#### >> Inspection requested via web by Deb Gooden House locked no answer at number provided.
|
ELE14-01135
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 1:15:45 PM | P | PASS |
|
|
The owner will meet you there to open the door. Please call me 20 minutes prior so I can make sure we can coordinate. Eddy at ###-####. Thanks Phone #: ###-#### >> Inspection requested via web by Eddy Udry p/s o/h rec ok
|
ELE14-00261
| Final | 5/13/2014 | 5/13/2014 | 5/13/2014 12:45:19 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt Final ok
|
ELE14-01202
| Electrical Rough-In | 5/12/2014 | 5/13/2014 | 5/13/2014 10:27:36 AM | A | PASS |
|
|
I would like a cover inspection they turned one big office into two offices we added outlets in the new wall and added 2 double switches for the two offices. The building will be open all day go in the front doors first door on left Phone #: ###-#### >> Inspection requested via web by Kevin Oderkirk Space 180 being split new office north end. Wall rough in ok cover
|
ELE14-01219
| Permanent Service | 5/13/2014 | 5/13/2014 | 5/13/2014 9:56:58 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack p/s o/h n ok
|
ELE14-01219
| Electrical Rough-In | 5/13/2014 | 5/13/2014 | 5/13/2014 9:56:57 AM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack 400.5(A)- #8 SEOOW 3 current carrying conductor cord max ampacity 35 amps, 50 amp over current installed
|
ELE14-01219
| Electrical Rough-In | 5/13/2014 | 5/13/2014 | 5/13/2014 9:56:31 AM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack 400.5(A)- # 8 SEOOW 3 current carrying conductor cord max ampacity 35 amps, 50 amp over current installed.
|
ELE14-01134
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 9:23:12 AM | A | NR |
|
|
troy Phone #: ###-#### Existing electrical boxes open, whips not terminated, GFCI protection needed for all 120 receptical outlets.
|
ELE12-02153
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 8:52:36 AM | A | PASS |
|
|
I looked back at my records and they indicated this was not a service change. If I remember right you came and looked at the trench for some shed power. Sorry its been so long and I am not much help. Phone #: ###-#### >> Inspection requested via web by Craig Korell Final ok
|