MEC14-01816
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 4:36:02 PM | P | PASS |
|
|
Please Call Robbie ###-#### @ Jims Heating Prior To Inspection Thank You Phone #: ###-#### >> Inspection requested via web by Manuel Acuna
|
MEC14-01826
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 3:43:35 PM | P | FAIL |
|
|
Contact homeowner for access at ###-#### Phone #: ###-#### >> Inspection requested via web by Amanda Drake - NEED TO PROVIDE CO2 SENSOR OUTSIDE BEDROOMS ON 2ND FLOOR.
|
MEC14-00946
| Final | 5/13/2014 | 5/13/2014 | 5/13/2014 3:16:35 PM | P | PASS |
|
|
final Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen
|
MEC14-01651
| Rough-in | 5/13/2014 | 5/13/2014 | 5/13/2014 2:40:59 PM | P | FAIL |
|
|
light test - grease duct Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen - PIN HOLES IN BOTH GREASE DUCTS.
|
MEC13-04437
| Final | 5/13/2014 | 5/13/2014 | 5/13/2014 2:03:22 PM | P | FAIL |
|
|
Codie w/TML requesting 1-2pm please call when going, thank you Phone #: ###-#### >> Inspection requested via web by Michele LaMott - VENT CONNECTOR IN A CRAWL SPACE IS REQUIRED TO BE B-VENT TO THE FURNACE CONNECTION. NEED TO CHANGE OUT SINGLE WALL PIPE TO B-VENT
|
MEC14-01795
| Pressure Test | 5/9/2014 | 5/13/2014 | 5/13/2014 1:28:46 PM | P | PASS |
|
|
Please contact Jason with any questions. Phone #: ###-#### >> Inspection requested via web by Lisa Whitney - 20LB GAS PRESSURE PASS
|
MEC13-01495
| Mec-Aging Inspection | 5/13/2014 | 5/13/2014 | 5/13/2014 11:48:36 AM | | CANC |
|
|
|
MEC14-00698
| Rough-in | 5/12/2014 | 5/13/2014 | 5/13/2014 11:34:12 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by April Thomas - NEED TO SUBMIT & HAVE A MANUAL J APRROVED
|
MEC14-00698
| Pressure Test | 5/12/2014 | 5/13/2014 | 5/13/2014 11:14:16 AM | A | PASS |
|
|
Pressure test for gas line & for hydronics Phone #: ###-#### >> Inspection requested via web by April Thomas - 20LB GAS PRESSURE PASS, 100LB HYDRONIC PASS FOR PATIO
|
MEC14-01825
| Pressure Test | 5/12/2014 | 5/13/2014 | 5/13/2014 10:34:21 AM | A | PASS |
|
|
Dave Phone #: ###-#### -20LB GAS PRESSURE PASS
|
MEC14-01448
| Final | 5/12/2014 | 5/13/2014 | 5/13/2014 10:05:06 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by AMANDA FARNSWORTH - THIS SHOULD HAVE BEEN A ROUGH IN. RESCHEDULED AS A ROUGH IN.
|
MEC14-01448
| Rough-in | 5/13/2014 | 5/13/2014 | 5/13/2014 10:04:05 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by AMANDA FARNSWORTH - FIRE/SMOKE DAMPERS OK
|
MEC14-01470
| Pressure Test | 5/13/2014 | 5/13/2014 | 5/13/2014 9:48:08 AM | A | PASS |
|
|
gaspiper miguel ###-#### >> Inspection requested via web by Dustin Rich-20LB GAS PRESSURE PASS
|
GCM14-00112
| GCM-Final | 5/12/2014 | 5/13/2014 | 5/13/2014 9:22:47 AM | A | PASS |
|
|
Matt ###-####
|
MEC12-03991
| Rough-in | 5/12/2014 | 5/13/2014 | 5/13/2014 8:56:14 AM | A | PART |
|
|
Brian Phone #: ###-#### >> Inspection requested via web by Michele LaMott - Trama, & patiant rooms ok cover.
|