Inspections for the day of: Wednesday, May 13, 2015.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01568 ELE-Aging Inspection5/13/20155/13/20155/13/2015 3:01:32 PM DONE
Still waiting on owner
ELE15-00410 Electrical Rough-In5/13/20155/13/20155/13/2015 2:48:51 PMPPASS
Treon Phone #: ###-#### 4th floor OR corridor areas grid rough in ok cover
ELE15-01401 Electrical Rough-In5/13/20155/13/20155/13/2015 1:28:41 PMPPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI Back patio 2 cans, fan, box in corner of lid cover rough in ok cover
GCE15-00076 GCE-Rough-In Permanent Service5/13/20155/13/20155/13/2015 1:01:27 PMPPASS
Terry ###-#### Rough in ok cover p/s u/g n ok
ELE15-00397 Final5/12/20155/13/20155/13/2015 11:49:45 AMAFAIL
Key in back weather proof outlet for house
Garage code 0713 Phone #: ###-#### Inspection requested via web by Emmet Bushman 230.79- For service on detached garage with more than 2 circuits disconnecting means shall be rated 60 amp minimum.
250.24(A)(5)- Grounded conductor shall not be connected to noncurrent carrying metal parts on load side of main disconnect,
408.36(D)- Plug in type back fed breakers shall be secured by additional means.
422.30- Range hood and house fan shall have disconnecting means.
ELE15-00400 Final5/12/20155/13/20155/13/2015 10:39:16 AMAFAIL
If you have any questions, please call the office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan 210.52(A)(2)(1)- Receptacle outlet shall be installed family room 2' wall space to left of fireplace. Receptacles located in cabinets do not qualify.
210.52(C)(1)- Receptacle outlet shall be installed to serve counter top by refrigerator with in 24" of edge and with in 4' of next receptacle.
210.51(D)- In main bath upstairs a receptacle outlet shall be installed for each basin and shall be ajacent to each basin.
422.30- Lock out provided for hood lock out shall be complete. Handle loop.
ELE15-01385 Electrical Rough-In5/12/20155/13/20155/13/2015 9:28:53 AMAPASS
For access please call Justin 1/2 hr prior to inspection. ###-#### Inspection requested via web by Terry Scott Master bath remodel rough in ok cover
ELE15-01371 Temporary Service5/12/20155/13/20155/13/2015 8:52:26 AMAPASS
Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE15-00972 Final5/13/20155/13/20155/13/2015 8:39:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok