Inspections for the day of: Wednesday, May 13, 2020.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01445 Final5/12/20205/13/20205/13/2020 2:15:38 PMANR
Floor receptacle has been installed below window wall.
Outdoor recep near eave is fed from indoor recep below it, which provides GFCI protection.
Owner should be home, call me with any questions or issues. Phone #: ###-#### Inspection requested via web by Dan Hilke Waiting for virtual inspection.
ELE20-01642 Final5/13/20205/13/20205/13/2020 2:10:42 PMPPASS
We should be ready late morning. Please call me to arrange inspection. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Final ok
ELE20-00849 Electrical Rough-In5/12/20205/13/20205/13/2020 2:10:17 PMPPASS
Screened-Ron Phone #: ###-#### Mens restroom only ok to cover
ELE19-04791 Electrical Rough-In5/12/20205/13/20205/13/2020 2:09:48 PMPPASS
This is for rough-in inspection of walls for three new offices in area C of the B26 Labs remodel project. Call Nick Solterbeck or Ron Pontius(###-####) and one of us will meet you at the B26 lobby. Phone #: ###-#### Inspection requested via web by Ron Pontius 3 offices walls only ok to cover
ELE20-01559 Final5/13/20205/13/20205/13/2020 12:49:28 PMPPASS
Call Barry with questions. 2088694676 Phone #: ###-#### Inspection requested via web by Lauren Norris Sub panel only final ok
ELE19-03568 Electrical Rough-In5/12/20205/13/20205/13/2020 12:48:52 PMPPASS
Jose Phone #: ###-#### Gazebo only rough in ok
ELE19-01403 Electrical Rough-In5/12/20205/13/20205/13/2020 10:57:56 AMPPASS
Rough in inspection for elevated deck pour of ramp 6-1. Phone #: ###-#### Inspection requested via web by John Mittleider Area listed ok to cover
ELE20-00856 Final5/12/20205/13/20205/13/2020 10:52:24 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Final ok
ELE20-00318 Final5/13/20205/13/20205/13/2020 10:24:29 AMPPASS
Need final for building final, thanks Phone #: ###-#### Inspection requested via web by Robert Schroder Temp service Final ok
ELE20-01520 Final5/12/20205/13/20205/13/2020 9:59:20 AMACANC
Phone #: ###-#### Inspection requested via web by Matthew White Needed re-inspect on rough in
ELE20-01548 Temporary Service5/12/20205/13/20205/13/2020 9:58:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Same Electric t/s u/g n ok
ELE20-01520 Electrical Rough-In5/13/20205/13/20205/13/2020 9:13:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Matthew White Corrections made rough in ok
ELE20-01617 Final5/12/20205/13/20205/13/2020 8:52:27 AMAPASS
Inspection requested via web by Terissa Morain Final ok
ELE20-01586 Permanent Service5/12/20205/13/20205/13/2020 8:44:24 AMAPASS
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg To be checked at final- EMT raintight fittings Shall be made wrench tight, Label Panel. p/s o/h rec ok