Inspections for the day of: Thursday, May 14, 2009.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC06-01613 Aging Inspection5/14/20095/14/20095/19/2009 8:00:29 AM DONE
ELE08-02428 ELE-Aging Inspection5/14/20095/14/20095/19/2009 7:29:25 AM PART
wsuc
ELE08-02484 ELE-Aging Inspection5/14/20095/14/20095/19/2009 7:28:50 AM PART
waiting for inspection request
ELE09-00800 Conference5/12/20095/14/20095/14/2009 4:45:51 PMPDONE
Herbert Please call 1 hr before going out Phone #: ###-#### ok
ELE09-00840 Electrical Rough-In5/14/20095/14/20095/14/2009 4:44:55 PMPPASS
paul Phone #: ###-#### ok basement
ELE09-00641 Final5/14/20095/14/20095/14/2009 3:28:11 PMPPASS
Ron Phone #: ###-####
ELE09-00641 Electrical Rough-In5/14/20095/14/20095/14/2009 3:27:24 PMPPASS
Ron Phone #: ###-#### needs boards to protect rpmex 3 locations owner will install ok
ESC08-00670 General Inspection5/14/20095/14/20095/14/2009 3:26:22 PMPPASS
ok
ELE08-03023 Final5/13/20095/14/20095/14/2009 3:09:27 PMPPART
Please provide final inspection. Phone #: ###-#### Internet Inspection Request from: Spencer
t/o ok card signed needs listing for xray, overhead xam rm lights, and microscopes
ESC09-00139 General Inspection5/14/20095/14/20095/14/2009 1:59:49 PMPPASS
ok
ELE09-00839 Electrical Rough-In5/14/20095/14/20095/14/2009 1:56:11 PMPFAIL
ron beckman Phone #: ###-#### corr. met contr. 300.4(D) parallel protection for flex,
348.24&30 flex bent too tight for radius, strap 12" of boxes, 358.30 strap emt within 3ft boxes, 230.70(A)(2) and BCC 04-05-31(A) service and subpanels not allowed in bathrooms
ESC09-00197 General Inspection5/14/20095/14/20095/14/2009 1:51:41 PMPPASS
ok
ELE09-00837 Electrical Rough-In5/14/20095/14/20095/14/2009 1:50:57 PMPPASS
ok
Internet Inspection Request from: Dan Rohl
ELE09-00710 Electrical Rough-In5/14/20095/14/20095/14/2009 12:52:18 PMPPASS
jack- underground. box for light Phone #: ###-#### ok
ELE09-00841 Permanent Service5/14/20095/14/20095/14/2009 12:17:01 PMPPASS
Robert Phone #: ###-#### p/s u/g rec. ok
ELE09-00841 Final5/14/20095/14/20095/14/2009 12:16:43 PMPPASS
Robert Phone #: ###-####
ELE09-00783 Conference5/14/20095/14/20095/14/2009 10:42:46 AMADONE
ok
ELE09-00805 Final5/13/20095/14/20095/14/2009 10:12:45 AMAPASS
final on service, homeowner got bench moved away from sub-panel in garage. Phone #: ###-#### Internet Inspection Request from: Andy Rose ok
ELE09-00730 Final5/13/20095/14/20095/14/2009 9:57:06 AMAFAIL
Please provide final inspection for the three newly added vacuums. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean called corr. 250.148, & 250.122 shall splice all equip grds together in outside j box and use #10 grd pigtail to grd box
ESC08-00999 General Inspection5/14/20095/14/20095/14/2009 8:55:31 AMAPASS
ok landscaping in progress
ELE09-00238 Final5/14/20095/14/20095/14/2009 8:53:14 AMAFAIL
Thanks! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn
called corr. 210.52(A) outlet spacing back covered porch, and fam rm, 210.52(C) needs outlet backsplash island counter, 410.2&16 clearence NE bed rm closet, 110.3 (A&B) needs access for jtub, and check all recepts and switches for power and correct wiring, put address at house
ELE09-00783 Conference5/12/20095/14/20095/14/2009 12:00:00 AMACANC
Danny Phone #: ###-####