Inspections for the day of: Wednesday, May 14, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00744 Electrical Rough-In5/14/20145/14/20145/14/2014 3:18:03 PMPCANC
bonding for lighting pole bases // Daryl Phone #: ###-#### called, explained that pole base grounding is for lightning protection per desin engineer specifications, electrical requires branch circuit and equipment grounding be done at final
ELE14-01231 Electrical Rough-In5/13/20145/14/20145/14/2014 2:51:30 PMPFAIL
Please call Jeff at ###-#### when on way. Thanks, Andrea. Phone #: ###-#### >> Inspection requested via web by Andrea Creek called, shall install receptacles per NEC 210.52, 2' wall shall have outlet, outlets shall not be over 6' from doorway, shall provide access to inspect wall- no sheetrock in storage, old metal boxes not enough cubic inch, wires cut short, insulation shall be removed for inspection, BCC no violations shall be retained
ELE14-00923 Final5/14/20145/14/20145/14/2014 2:42:26 PMPPASS
Can you please call ahead of time so I can make sure there is someone there to open the door and let you into the building. Thanks Mark Phone #: ###-#### >> Inspection requested via web by Mark Hennequin ok final
ELE14-00577 Final5/13/20145/14/20145/14/2014 1:58:26 PMPPASS
Jon. Early if possible. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy ok final, signed card
ELE14-01093 Electrical Rough-In5/13/20145/14/20145/14/2014 1:30:33 PMPCANC
Brady Phone #: ###-#### called, nh, told to recall and note to call in advance for inspection
ELE14-00473 Final5/14/20145/14/20145/14/2014 12:59:10 PMPPASS
If locked call me for key location. Thank You!! >> Inspection requested via web by Julie Schroder ok final
ELE14-00455 Final5/14/20145/14/20145/14/2014 12:18:55 PMPPASS
Garage code 1979E Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
ELE13-01476 Electrical Rough-In5/13/20145/14/20145/14/2014 10:28:42 AMAPASS
Cody Phone #: ###-#### break room and dark room walls only ok cover
ELE14-01217 Rough-In Permanent Service5/12/20145/14/20145/14/2014 9:43:42 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
ELE14-01207 Temporary Service5/12/20145/14/20145/14/2014 9:34:56 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE14-00631 Final5/13/20145/14/20145/14/2014 9:01:04 AMAPASS
CODE 4224 ANY ? CALL BILL ###-#### Phone #: ###-#### >> Inspection requested via web by Bob Glenn ok final
ELE14-00986 Rough-In Permanent Service5/13/20145/14/20145/14/2014 8:54:42 AMANR
House is open. Phone #: ###-#### >> Inspection requested via web by Clay Morgan called, left message to call back, nm cable over panel shall be secured within 12" of panel, damaged nm in 4 square box, no ground rods installed, no rear receptacle installed, shall seal wiring entering warm area from outside per NEC 300.7