Inspections for the day of: Wednesday, May 14, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-01088 Electrical Rough-In5/13/20145/14/20145/14/2014 3:57:54 PMPPASS
Phone #: ###-#### >> Inspection requested via web by ron spencer Rough-in ok cover complete rewire. Motorized tub and steamer not on site at time of rough-in inspection. Boise Municipal Code 4-05-32 Cod violation not to be retained Exsiting code violations with pool panel, No GFCI protection for pool equipment or lighting
MIS14-00106 ELE-Conference5/14/20145/14/20145/14/2014 3:12:19 PMPDONE
Licences electrical contractor installing up lighting as a test for management approval without first securing an electrical permit. Double fee in required
ELE14-01242 Conference5/14/20145/14/20145/14/2014 2:46:10 PMPDONE
please call me to schedule time to meet on site thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Discussed elecrtrical requirements for missing concrete encased electrode, receptacle layout for spiral staircase
ELE14-01199 Final5/14/20145/14/20145/14/2014 2:04:58 PMPNR
Duane O''Reilly is contact at ###-####. thanks. Phone #: ###-#### >> Inspection requested via web by Debby Pierce Not ready at this time, power has not been. energized
ELE13-03042 Conference5/14/20145/14/20145/14/2014 12:34:39 PMPDONE
Ryan Phone #: ###-#### Discussed raceway to pool equipment service gear and grounding
ELE14-01234 Electrical Rough-In5/14/20145/14/20145/14/2014 12:08:18 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Brad Girard Rough-in ok cover kitchen/ dinning remodel
ELE14-01172 Temporary Service5/14/20145/14/20145/14/2014 10:13:17 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
ELE14-01232 Final5/13/20145/14/20145/14/2014 9:58:04 AMANR
Phone #: ###-#### >> Inspection requested via web by kevin blackmon not ready for final at this time
ELE14-01232 Rough-In Permanent Service5/14/20145/14/20145/14/2014 9:55:16 AMAPASS
Phone #: ###-#### >> Inspection requested via web by kevin blackmon Rough-in p/s u/g n ok
ELE14-01199 Permanent Service5/14/20145/14/20145/14/2014 9:32:16 AMPPASS
p/s o/h rec ok
ELE14-01002 Final5/13/20145/14/20145/14/2014 9:16:48 AMANH
If you have any questions, please call Calvin ###-####. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan no access, No Answer at door
ELE13-02314 Final5/13/20145/14/20145/14/2014 8:35:33 AMAFAIL
Jay-call homeowner for access Doug @ ###-#### Phone #: ###-#### NEC 210.12(B) Arc-Fault Interrupter protection is required for new master bedroom circuit. NEC 410.16(B) Open lamp fixture in master bedroom closet
ELE13-01839 Final5/13/20145/14/20145/14/2014 8:29:36 AMAPASS
Douglas Phone #: ###-#### final ok