Inspections for the day of: Monday, May 14, 2018.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-01795 Final5/14/20185/14/20185/14/2018 2:28:20 PMPFAIL
Please call John at ###-#### with 30 minutes heads up. Phone #: ###-#### Inspection requested via web by Barbara Szurgot
Called contact, no answer, mail box full unable to leave message. Call electrical contractor and informed a building permit required for solar panel installations. Permit search listed no BLD for this address.
ELE16-03745 Final5/12/20185/14/20185/14/2018 2:17:32 PMPFAIL
This job was completed some time ago. Call Aaron at the number above if you have any questions Phone #: ###-#### Inspection requested via web by Dana Vance
Unable to verify listing and disconnecting means on double sided free standing sign.
ELE18-01789 Electrical Rough-In5/12/20185/14/20185/14/2018 1:56:26 PMPPART
Partial rough in Phone #: ###-#### Inspection requested via web by Don Conley
kitchen/ family room area ceiling foam insulation only rough in ok cover
ELE18-01634 Electrical Rough-In5/11/20185/14/20185/14/2018 1:20:27 PMPPASS
Inspection requested via web by David McClellan
Wiring in stairway will be covered as per 110.27. At final all will be new TR receptacles and switches. Rough in ok cover
ELE18-01205 Electrical Rough-In5/11/20185/14/20185/14/2018 12:45:50 PMAPART
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Corridor grid as noted on contractor print rough in ok cover
ELE18-00900 Electrical Rough-In5/13/20185/14/20185/14/2018 10:33:55 AMAPASS
Equipotential bonding grid ready for inspection. Access is around right side of condos. Stan is manager-###-#### Phone #: ###-#### Inspection requested via web by Craig Korell
Perimeter and luminaire shell bond rough in ok cover
ELE18-01751 Electrical Rough-In5/13/20185/14/20185/14/2018 9:44:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Brad Rowen
GFCI to bath fan located in shower to be in hall on lighting circuit, receptacle located low in bath has 14 ga. wire junctioning in same box as 12 ga for receptacle.
Rough in ok cover
ELE18-01151 Electrical Rough-In5/11/20185/14/20185/14/2018 9:26:34 AMAPASS
Austin Jensen, Crew Lead: ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting All equipment still on ground
Listings confirmed rough in ok
ELE18-01049 Final5/14/20185/14/20185/14/2018 9:13:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Ron Zimmerman
Final ok