Inspections for the day of: Monday, May 14, 2018.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-01386 Mec-Aging Inspection5/14/20185/14/20185/14/2018 4:33:52 PM CANC
wip
MEC18-02119 Rough-in5/14/20185/14/20185/14/2018 4:33:00 PMPPASS
Please call Max if you need anything. ###-####. Thanks! Inspection requested via web by Floyd Floyd Peek - Duct work doesn't match Manual J design
MEC18-01726 Final5/14/20185/14/20185/14/2018 3:36:45 PMPFAIL
Inspection requested via web by Floyd Floyd Peek - Need service disconnect swith on 2 of the furnaces. Need upper combustion air for 2 of the furnaces, Need 6" clearance to combustables on single walls flue. (pvc condensate)
MEC17-04910 Pressure Test5/14/20185/14/20185/14/2018 2:46:32 PMPPASS
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 20lb gas pass on undergound piping to fire pit
MEC18-01866 Rough-in5/14/20185/14/20185/14/2018 1:55:38 PMPPASS
Cover inspection Phone #: ###-#### Inspection requested via web by RaChelle Frisbee - Okay to cover hard lids
MEC18-00272 Rough-in5/11/20185/14/20185/14/2018 12:03:23 PMAFAIL
Rough in for Roof duct Contact Antonio ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Need to finish sealing the 4th system
MEC18-01435 Rough-in5/11/20185/14/20185/14/2018 9:21:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige - 100lb hydronics pass for 2 remaining systems