MEC19-00932
| Rough-in | 5/14/2019 | 5/14/2019 | 5/14/2019 3:59:07 PM | P | PASS |
|
|
Builder changed unit. Needs to re-inspected. Phone #: ###-#### Inspection requested via web by Dan Otero[- fireplace r/i ok
|
MEC19-01970
| Final | 5/10/2019 | 5/14/2019 | 5/14/2019 3:27:25 PM | P | PASS |
|
|
Afternoon inspection if possible please. Homeowner will be home from 12-4. Thank you. Phone #: ###-#### Inspection requested via web by Julie McMillan- furnace a/c coil co ok
|
MEC19-01420
| Final | 5/8/2019 | 5/14/2019 | 5/14/2019 2:43:59 PM | P | PASS |
|
|
Please call Tom in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnacve a/c coil co ok
|
MEC19-02005
| Final | 5/14/2019 | 5/14/2019 | 5/14/2019 1:53:20 PM | P | PASS |
|
|
Jeremy ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co ok
|
MEC19-01972
| Rough-in | 5/14/2019 | 5/14/2019 | 5/14/2019 1:04:14 PM | P | PASS |
|
|
Light test on 52 inch long grease duct. We will have it ready at 1:00 Phone #: ###-#### Inspection requested via web by Drew Tverdy- light test pass 52" piece with offset to hood- will look at roof on next inspection
|
MEC19-01992
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 10:55:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Julie McMillan- final ok
|
MEC19-01992
| Rough-in | 5/14/2019 | 5/14/2019 | 5/14/2019 10:55:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Julie McMillan- R/I ok on 2 bath fans, return ducting and supply runs
|
MEC19-01868
| Rough-in | 5/13/2019 | 5/14/2019 | 5/14/2019 10:36:21 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 24 inch wide platform still not installed from access to atticin stairwell to furnace platform- reinspection fee issued for multiple attempts
|
MEC19-01549
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 9:52:25 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- need to witness flue test- furnace a/c coil co ok
|
MEC19-01934
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 9:42:18 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- arma flex needs uv protection completed missing some areas- pull out on disconnect at a/c has one side thats loose
|
MEC18-03760
| Final | 5/13/2019 | 5/14/2019 | 5/14/2019 9:03:28 AM | A | NH |
|
|
Please try again to inspect then expire it if they are not home. I sent a certified letter to ask them to call me to schedule the inspection and did not get a reply. Phone #: ###-#### Inspection requested via web by Mary LaFayette- no one home- left notice front door
|
MEC19-00932
| Rough-in | 5/13/2019 | 5/14/2019 | 5/14/2019 8:47:29 AM | A | CANC |
|
|
Mechanical Rough in inspection. Inspection requested via web by Dan Otero- per phone call with Dan-
|
MEC18-04743
| Mec-Aging Inspection | 5/14/2019 | 5/14/2019 | 5/14/2019 8:44:05 AM | | CANC |
|
|
|
MEC18-04743
| DOC - Permit Expired | 5/14/2019 | 5/14/2019 | 5/14/2019 8:43:56 AM | A | PASS |
|
|
work done on different permit
|
MEC19-01650
| Rough-in | 5/13/2019 | 5/14/2019 | 5/14/2019 8:42:37 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- outside air needs to be 8" round to each unit per prints and cannot tie in R/A register can needs to tie into plenum both are ran in 6" to 8" wye at wall- print M-1 shows 2 firedampers in chase first floor none are installed- electric heater in 1st floor stairwell needs installed- missing supply and transfer in closet SW corner 1st floor per prints- whos doing gas line ?- left correction notice front window
|