MEC20-01889
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 3:26:21 PM | P | PASS |
|
|
Please call our installer Blake on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok
|
MEC20-00853
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 3:08:19 PM | P | FAIL |
|
|
AC: 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves- 1- b vent in garage needs 1" clearance to sheetrock wall at ceiling penetration 2- insulation on return air plenum needs taped at ceiling and bare metal on east side needs addressed
|
MEC19-05617
| Final | 5/14/2020 | 5/14/2020 | 5/14/2020 2:26:07 PM | P | PART |
|
|
Please call/text Dustin at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- need version 2 approved drawings onsite- item 219 and 222 on M201 needs engineer approval for removing 1booster exhaust fan item 222none installed and 1 motorized damper item 219 only 1 installed not 2- please clarify from engineering- rest is good
|
MEC19-05298
| Final | 5/14/2020 | 5/14/2020 | 5/14/2020 2:15:15 PM | P | PASS |
|
|
CAMERON IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- gas piping final ok
|
MEC20-01258
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 1:27:11 PM | P | PASS |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
|
MEC20-01890
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 12:53:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- b vent needs 1" clearance to sheetrock at ceiling and trim ring installed and firecaulked- need to secure b vent to structure in approved manner to garage wall- home owner stated that b vent will have framing around it not installed at this time will need it in place to check clearances- recall in when ready
|
MEC20-01779
| Final | 5/14/2020 | 5/14/2020 | 5/14/2020 11:30:47 AM | P | PASS |
|
|
Electrical Permit has been pulled. Please close Mechanical. Phone #: ###-#### Inspection requested via web by Arielle Hendricks- electrical permit pulled
|
MEC20-01690
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 10:48:15 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok- need locking caps on a/c service ports- vinyl tubing not approved material for condesate drain and has kink in line at ceiling and drain needs grade- route new 3/4" pvc drain to existing primary drain off coil behind freezer in 3/4" pvc with barbed fitting near pump- send pic for reinspect
|
MEC20-01024
| Final | 5/13/2020 | 5/14/2020 | 5/14/2020 10:09:25 AM | A | PASS |
|
|
Fernando Phone #: ###-####- final ok- pics sent via text
|
MEC20-00278
| Rough-in | 5/14/2020 | 5/14/2020 | 5/14/2020 9:28:07 AM | A | PASS |
|
|
R/I on pool room ok- installing as catagory 1 fluing via b vent
|
MEC20-01485
| Rough-in | 5/13/2020 | 5/14/2020 | 5/14/2020 9:00:25 AM | A | PASS |
|
|
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok phase 1- ok for ceiling tiles-temp occupancy ok phase 1 lobby, conference and 2 offices- c line west existing no work registers remained
|
MEC19-04537
| Mec-Aging Inspection | 5/14/2020 | 5/14/2020 | 5/14/2020 8:09:37 AM | | CANC |
|
|
permit finaled
|
MEC19-04537
| DOC - Permit Finaled | 5/14/2020 | 5/14/2020 | 5/14/2020 8:09:21 AM | A | PASS |
|
|
electrical permit issued and inspected
|