Inspections for the day of: Thursday, May 14, 2020.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-01889 Final5/13/20205/14/20205/14/2020 3:26:21 PMPPASS
Please call our installer Blake on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok
MEC20-00853 Final5/13/20205/14/20205/14/2020 3:08:19 PMPFAIL
AC: 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves-
1- b vent in garage needs 1" clearance to sheetrock wall at ceiling penetration
2- insulation on return air plenum needs taped at ceiling and bare metal on east side needs addressed
MEC19-05617 Final5/14/20205/14/20205/14/2020 2:26:07 PMPPART
Please call/text Dustin at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- need version 2 approved drawings onsite- item 219 and 222 on M201 needs engineer approval for removing 1booster exhaust fan item 222none installed and 1 motorized damper item 219 only 1 installed not 2- please clarify from engineering- rest is good
MEC19-05298 Final5/14/20205/14/20205/14/2020 2:15:15 PMPPASS
CAMERON IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- gas piping final ok
MEC20-01258 Final5/13/20205/14/20205/14/2020 1:27:11 PMPPASS
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
MEC20-01890 Final5/13/20205/14/20205/14/2020 12:53:29 PMPFAIL
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- b vent needs 1" clearance to sheetrock at ceiling and trim ring installed and firecaulked- need to secure b vent to structure in approved manner to garage wall- home owner stated that b vent will have framing around it not installed at this time will need it in place to check clearances- recall in when ready
MEC20-01779 Final5/14/20205/14/20205/14/2020 11:30:47 AMPPASS
Electrical Permit has been pulled. Please close Mechanical. Phone #: ###-#### Inspection requested via web by Arielle Hendricks- electrical permit pulled
MEC20-01690 Final5/13/20205/14/20205/14/2020 10:48:15 AMAFAIL
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok- need locking caps on a/c service ports- vinyl tubing not approved material for condesate drain and has kink in line at ceiling and drain needs grade- route new 3/4" pvc drain to existing primary drain off coil behind freezer in 3/4" pvc with barbed fitting near pump- send pic for reinspect
MEC20-01024 Final5/13/20205/14/20205/14/2020 10:09:25 AMAPASS
Fernando Phone #: ###-####- final ok- pics sent via text
MEC20-00278 Rough-in5/14/20205/14/20205/14/2020 9:28:07 AMAPASS
R/I on pool room ok- installing as catagory 1 fluing via b vent
MEC20-01485 Rough-in5/13/20205/14/20205/14/2020 9:00:25 AMAPASS
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok phase 1- ok for ceiling tiles-temp occupancy ok phase 1 lobby, conference and 2 offices- c line west existing no work registers remained
MEC19-04537 Mec-Aging Inspection5/14/20205/14/20205/14/2020 8:09:37 AM CANC
permit finaled
MEC19-04537 DOC - Permit Finaled5/14/20205/14/20205/14/2020 8:09:21 AMAPASS
electrical permit issued and inspected