Inspections for the day of: Monday, May 15, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04313 ELE-Aging Inspection5/15/20065/15/20065/19/2006 9:56:38 AM DONE
see final
ELE06-01692 Permanent Service5/12/20065/15/20065/15/2006 4:30:14 PMPNR
tim ###-#### still didn't have original panel out of wall, went back later, nh, called and they were getting pipe cut. Told owner to call tomorrow when ready.They have a gen set for freezer.
ELE05-03620 Final5/15/20065/15/20065/15/2006 3:58:40 PMPPASS
Kevin; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final
ELE06-01486 Rough-In Permanent Service5/15/20065/15/20065/15/2006 3:25:51 PMPPASS
Kevin; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ric ok, p/s u/g n ok
ELE05-02631 ELE-Aging Inspection5/15/20065/15/20065/15/2006 2:47:56 PM NR
no call for final, suc
ELE06-00510 ELE-Aging Inspection5/15/20065/15/20065/15/2006 2:23:38 PM DONE
see final
ELE06-00510 Final5/15/20065/15/20065/15/2006 2:23:16 PMPPASS
looked at sign, ok to final
ELE06-01702 Electrical Rough-In5/15/20065/15/20065/15/2006 2:01:03 PMPPASS
###-#### - mike ok to cover front porch ceilings only
ELE06-01678 Rough-In Permanent Service5/15/20065/15/20065/15/2006 1:16:53 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook corr made, ric ok, p/s u/g n ok
ELE06-01082 Final5/12/20065/15/20065/15/2006 11:39:20 AMAPASS
Please call if you have any questions and/or concerns; Phone #: ###-#### Internet Inspection Request from: Eric Shaner lookrd at sign, ok to final
ELE06-01670 Temporary Service5/11/20065/15/20065/15/2006 10:18:38 AMPPASS
###-#### - steve t/s u/g n ok
ELE06-01671 Temporary Service5/11/20065/15/20065/15/2006 9:42:52 AMAPASS
###-#### - steve t/s u/g n ok
ELE06-01672 Temporary Service5/11/20065/15/20065/15/2006 9:42:13 AMAPASS
###-#### - steve called contr, left survey, 210.53(G) the upper end of the electrode shall be flush with or below ground unless protected against physical damage , t/s u/g n ok
ELE03-04124 Final5/12/20065/15/20065/15/2006 9:00:30 AMAPASS
Scheduled by a contractor via Hello! on 5/12/2006 at 2:25:28 PM. Contact: ###-####. corr made, ok to final
ELE06-01678 Rough-In Permanent Service5/14/20065/15/20065/15/2006 8:27:04 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook called contr, left corr notice, nec 334.30 nm cable shall be stapled within 12" of enclosure, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A)(1) wall space over 6' shall have recpt, BCC all make-up shall be done,a/c disc set