Inspections for the day of: Thursday, May 15, 2014.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00244 ELE-Aging Inspection5/15/20145/15/20145/19/2014 2:27:43 PM PASS
final ok
ELE11-02161 ELE-Aging Inspection5/15/20145/15/20145/16/2014 3:01:58 PM DONE
left message
ELE10-02424 ELE-Aging Inspection5/15/20145/15/20145/16/2014 2:59:52 PM DONE
left message
ELE12-02238 ELE-Aging Inspection5/15/20145/15/20145/16/2014 2:50:25 PM DONE
spoke with secratary ,put on hold ,i finally hung up after waiting
ELE14-01043 Final5/15/20145/15/20145/15/2014 4:08:13 PMPPASS
Contact: Jeremy Thornock Phone #: ###-#### >> Inspection requested via web by Deb Gooden final ok
ELE14-00319 Electrical Rough-In5/15/20145/15/20145/15/2014 3:52:54 PMPPART
Ceiling Cover inspection Phone #: ###-#### >> Inspection requested via web by Kristopher Wilson ok to cover only in areas as per walk thru
ELE14-00488 Final5/15/20145/15/20145/15/2014 3:00:47 PMPFAIL
Mark Phone #: ###-#### shower trim needed for upst. shower for wet location. box extensions needed for kitchen backsplash where box is more than 1/4" to finish surface. flexable conduit to a/c not rated for wet location. Identify garage disconnect switch as disconnect. Need 50 % energy saving lamps as per boise municipal code, fix loose receptacles, nm cable in island needs to be protected from phisical damage
ELE14-01075 Final5/15/20145/15/20145/15/2014 1:40:04 PMPPASS
Phone #: ###-#### >> Inspection requested via web by danny perrine final ok
GCE14-00047 GCE-Final5/15/20145/15/20145/15/2014 1:13:51 PMPPASS
aaron ###-#### final on shop bldg. ok
ELE14-01240 Permanent Service5/15/20145/15/20145/15/2014 12:49:21 PMPPASS
Service change on garage in back alley. Sorry for the mistake yesterday Rex. Thanks, Eric Phone #: ###-#### >> Inspection requested via web by Eric Schroeder p/s o/h rec ok
ELE14-00386 Final5/14/20145/15/20145/15/2014 11:06:07 AMAFAIL
call for access. Phone #: ###-#### >> Inspection requested via web by Greg Idsinga 314.20 kitchen receptacles need box extensions where more than 1/4 to face of box
ELE14-01017 Electrical Rough-In5/14/20145/15/20145/15/2014 10:10:52 AMAPASS
Jason Gayhtwaite is the contact Phone #: ###-#### >> Inspection requested via web by Kelly Felin rough in garage walls ok to cover
ELE14-00972 Final5/14/20145/15/20145/15/2014 9:37:18 AMAPASS
Call David at ###-#### for access code. Phone #: ###-#### >> Inspection requested via web by David Nelson final ok
GCE13-00173 GCE-Permanent Service5/14/20145/15/20145/15/2014 9:12:43 AMAPASS
Kevin ###-#### p/s u/g n ok