PLM17-00057
| PLM-Aging Inspection | 5/15/2018 | 5/15/2018 | 5/17/2018 8:23:25 AM | | PEND |
|
|
spoke with Mark Luhaun at the job site. He will gat an update from Andrew Phelps. Gene from Coonse Well Drilling contacted me do get info. I will meet Gene on the site when he can schedule.
|
PLM18-02009
| Final | 5/15/2018 | 5/15/2018 | 5/15/2018 2:09:04 PM | P | NH |
|
|
is ready for inspection now, contact owner for entry ###-####766 Phone #: ###-#### Inspection requested via web by bob pond. called but no answer. not home tagged door to call
|
PLM18-01430
| Sprinkler (Final) | 5/14/2018 | 5/15/2018 | 5/15/2018 12:31:23 PM | A | PASS |
|
|
Replaced class 100 with 160 to PVB as requested. Thank You. Phone #: ###-#### Inspection requested via web by debbie long
|
PLM18-01877
| Plumbing Rough-in | 5/14/2018 | 5/15/2018 | 5/15/2018 12:24:00 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK. The autowasher cannot wet vent on top of the laundry sink. Reverse the order or install two risers. Call with any questions. ###-####
|
PLM18-01983
| Pressure Test | 5/14/2018 | 5/15/2018 | 5/15/2018 11:48:33 AM | A | PASS |
|
|
please call our technician greg in route 2089415555 Phone #: ###-#### Inspection requested via web by Rusty Karel. Sewer replacement
|
PLM18-01983
| DOC - Permit Finaled | 5/15/2018 | 5/15/2018 | 5/15/2018 11:48:09 AM | P | PASS |
|
|
|
PLM18-01944
| Final | 5/14/2018 | 5/15/2018 | 5/15/2018 11:41:25 AM | A | PASS |
|
|
Please use Anthony Scano (EPS) as the point of contact. Thank you. Phone #: ###-#### Inspection requested via web by Ben Davis-do they need a building permit? This inspection includes the rough-in and final.
|
PLM18-01929
| Water and/or Sewer | 5/15/2018 | 5/15/2018 | 5/15/2018 11:21:45 AM | P | PART |
|
|
System needs to be put under test. OK to cover the lateral due to depth.
|
PLM18-01995
| Sprinkler (Final) | 5/14/2018 | 5/15/2018 | 5/15/2018 11:12:09 AM | A | PASS |
|
|
Please contact Lupe @ ###-#### for any questions. Phone #: ###-#### Inspection requested via web by Marisela Huitron
|
PLM18-01573
| Final | 5/14/2018 | 5/15/2018 | 5/15/2018 10:51:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Raul Castanon
|
PLM18-02006
| Water and/or Sewer | 5/14/2018 | 5/15/2018 | 5/15/2018 10:36:01 AM | A | PASS |
|
|
Inspection requested via web by matt ford
|
PLM18-02006
| DOC - Permit Finaled | 5/15/2018 | 5/15/2018 | 5/15/2018 10:35:50 AM | P | PASS |
|
|
|
PLM18-02005
| Water and/or Sewer | 5/14/2018 | 5/15/2018 | 5/15/2018 10:35:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by matt ford
|
PLM18-02005
| DOC - Permit Finaled | 5/15/2018 | 5/15/2018 | 5/15/2018 10:35:25 AM | P | PASS |
|
|
|
PLM18-00191
| Final | 5/14/2018 | 5/15/2018 | 5/15/2018 10:14:37 AM | A | FAIL |
|
|
JEREMY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. 1. Install a running trap on the indirect waste to the warming trays. 2. Seal all fixtures to the wall. 3. Label all backflow assemblies. 4. The condensate drain on the water heater cannot drain outside; drain to an approved receptor.
|
PLM17-04814
| Final | 5/14/2018 | 5/15/2018 | 5/15/2018 9:49:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs
|
PLM18-01729
| Final | 5/14/2018 | 5/15/2018 | 5/15/2018 9:24:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone
|
PLM18-01991
| Sprinkler (Final) | 5/14/2018 | 5/15/2018 | 5/15/2018 9:07:31 AM | P | CANC |
|
|
Thank You. Phone #: ###-#### >> Inspection requested via web by debbie long Inspection cancelled from web by: debbie long
|
PLM18-01929
| Water and/or Sewer | 5/10/2018 | 5/15/2018 | 5/15/2018 8:52:32 AM | A | PEND |
|
|
Sewer Service Inspection Phone #: ###-#### Inspection requested via web by Taylor Landa. Consultation
|
PLM18-01951
| Water and/or Sewer | 5/10/2018 | 5/15/2018 | 5/15/2018 8:22:56 AM | P | CANC |
|
|
>> Inspection requested via web by Dan Bastian Inspection cancelled from web by: Dan Bastian
|