Inspections for the day of: Wednesday, May 16, 2007.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03803 ELE-Aging Inspection5/16/20075/16/20075/23/2007 7:23:41 AM DONE
see final
ELE07-01114 Electrical Rough-In5/16/20075/16/20075/16/2007 2:45:33 PMPPASS
Scheduled by a contractor via Hello! on 5/16/2007 at 9:12:08 AM. Contact: ###-####. light potting ok, pool
ELE07-01436 Electrical Rough-In5/16/20075/16/20075/16/2007 2:42:58 PMPPASS
jerad Note: please call 1/2 hr prior; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles pool light potting ok, equipotential plane ok to pour, includes ladders etc
ELE07-01518 Final5/16/20075/16/20075/16/2007 2:00:18 PMPPASS
craig--please call homeowner for access at least 1/2 hr prior at ###-####; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE07-00794 Electrical Rough-In5/16/20075/16/20075/16/2007 1:27:14 PMPPASS
2nd floor ceiling ok to cover except halls
ELE07-00794 Permanent Service5/16/20075/16/20075/16/2007 1:26:12 PMPCANC
Jesse; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt wrong type inspection, see ri
ELE07-01371 Electrical Rough-In5/15/20075/16/20075/16/2007 12:30:59 PMPCANC
carl ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith wrong type request
ELE07-01371 Rough-In Permanent Service5/16/20075/16/20075/16/2007 12:30:23 PMPPASS
carl ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok, p/s o/h n ok
ELE07-01768 Final5/15/20075/16/20075/16/2007 10:30:50 AMAPASS
Nick ; Phone #: ###-#### Internet Inspection Request from: Darla Downs called contr id meters and strap riser
ELE07-01768 Permanent Service5/16/20075/16/20075/16/2007 10:14:45 AMAPASS
Nick ; Phone #: ###-#### Internet Inspection Request from: Darla Downs p/s rec exst meter pak ok
ELE07-01279 Rough-In Permanent Service5/15/20075/16/20075/16/2007 9:58:46 AMAFAIL
Between Raymond and Liberty on Poplar. Phone #: ###-#### Internet Inspection Request from: Justin Yount called contr, left corr notice, nec 230.2 a building shall be supplied by only 1 service, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 314.16 boxes shall have free space for conductors, BCC all make-up shall be done, all u/g shall be inspected prior to cover, service will be done with ri
ELE07-01280 Final5/15/20075/16/20075/16/2007 9:57:02 AMACANC
Between Raymond and Liberty on Poplar. Phone #: ###-#### Internet Inspection Request from: Justin Yount called contr, wrong type inspection told to check when scheduling
ELE07-01280 Rough-In Permanent Service5/16/20075/16/20075/16/2007 9:55:53 AMAFAIL
Between Raymond and Liberty on Poplar. Phone #: ###-#### Internet Inspection Request from: Justin Yount called contr, left corr notice, 314.16 boxes shall have free space for conductors, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 230.2 only 1 service to building shall be installed, BCC all boxes and make-up shall be done, u/g shall be inspected before cover, service to be done at ri, gec connected in crawl space
ELE07-01577 Final5/15/20075/16/20075/16/2007 8:38:15 AMAPASS
Deck Replacement -Equipotential - FINAL Insp
Contact Rick @###-#### or Kelly @ ###-#### Phone #: ###-#### Internet Inspection Request from: Kelly Felin ok to final
ELE07-01769 Electrical Rough-In5/15/20075/16/20075/16/2007 8:17:48 AMAPASS
shawn ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called elect for more nailplates, ric ok
ELE07-01769 Final5/15/20075/16/20075/15/2007 3:40:45 PMACANC
shawn; Phone #: ###-#### Internet Inspection Request from: Patricia Smith Inspection cancelled from web by: Patricia Smith