ELE05-03962
| Electrical Rough-In | 5/16/2007 | 5/16/2007 | 5/16/2007 3:36:58 PM | P | NR |
|
|
Check Pool Bonding Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contractor wire mesh not tied together, wire mesh not off ground, & needs #8 solid cu wire for bonding.
|
ELE07-01694
| Electrical Rough-In | 5/16/2007 | 5/16/2007 | 5/16/2007 3:34:09 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 5/16/2007 at 9:07:02 AM. Contact: ###-####. ok cover ri buildings only
|
ELE07-01766
| Electrical Rough-In | 5/16/2007 | 5/16/2007 | 5/16/2007 2:22:59 PM | P | PASS |
|
|
ok pool light potting
|
ELE07-01766
| Permanent Service | 5/16/2007 | 5/16/2007 | 5/16/2007 2:21:03 PM | P | CANC |
|
|
Swimming Pool - Potting Inspection If Questions - Kelly @ ###-#### Phone #: ###-#### Internet Inspection Request from: Kelly Felin wrong type inspection
|
ELE07-00075
| Permanent Service | 5/16/2007 | 5/16/2007 | 5/16/2007 1:31:47 PM | P | PASS |
|
|
Daniel; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h reconnect ok note did not see sub panel or beyond.
|
ELE07-01785
| Electrical Rough-In | 5/16/2007 | 5/16/2007 | 5/16/2007 1:04:07 PM | P | PASS |
|
|
Jeremy ###-#### ok cover ri
|
ELE07-01767
| Rough-In Permanent Service | 5/15/2007 | 5/16/2007 | 5/16/2007 11:57:31 AM | A | PASS |
|
|
bob ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok cover ri p/s u/g n ok
|
ELE07-00489
| Electrical Rough-In | 5/15/2007 | 5/16/2007 | 5/16/2007 11:56:35 AM | A | PART |
|
|
dennis - before 10, cement coming at 10 AM; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok cover under slab conduit & boxes anop
|
ELE07-01688
| Permanent Service | 5/16/2007 | 5/16/2007 | 5/16/2007 9:46:42 AM | A | PASS |
|
|
p/s u/g n ok
|
ELE07-01688
| Electrical Rough-In | 5/15/2007 | 5/16/2007 | 5/16/2007 9:45:49 AM | A | PASS |
|
|
if any issues please call James Sanderson at ###-####. Thanks, Andrea. Phone #: ###-#### x0000 Internet Inspection Request from: Andrea Creek ok cover ri
|
ELE07-00916
| Electrical Rough-In | 5/15/2007 | 5/16/2007 | 5/16/2007 9:06:14 AM | A | PART |
|
|
Ran EMT and wires for a new exterior WP switch beside back door to control the new pool light. Wired a WP GFCI receptacle beside the PVC j-box on the end of the pool shed. Irreversibly bonded the #8 solid copper to the two existing ones beside the pool equipment. The pool company potted the pool light ground/bond connection. Owner is elderly and uses a walker so be patient at the front door. Thanks!!! Tech/Brian/###-#### Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok ri on conduit & equipment bonding note did not see light potting pool filled with water.
|