Inspections for the day of: Wednesday, May 16, 2007.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD06-01095 BLD-Final5/15/20075/16/20075/16/2007 4:46:08 PMPNR
chris - please call 1/2 hr prior to inspection; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
BLD06-00941 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 3:47:40 PMPPASS
kenny; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD06-01784 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 2:28:29 PMPPASS
pat - exterior; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. soffit insul ok. perimeter walls ok to insul.
BLD07-00603 BLD-Final5/15/20075/16/20075/16/2007 1:55:17 PMPPART
Steve; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. final insp. ok. Will doc final, once mech has finaled.
BLD07-00946 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 12:50:23 PMANR
vern - partial insulation ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
BLD07-00051 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 10:58:50 AMAFAIL
c/n posted. ok to insul. 1. nail off all simpson hangars.
2. repair top plate in garage at gas piping.
3. provide min 3nails for truss to top plate connection.
4. provide min 4 8d nails on straps either side.
5. header required upstairs at doorway were truss bearing occurs.
6. provide fireblocking at furouts.
7. foam seal tub drain at main floor.
8. provide engineering for portal frame.
9. provide code compliant winder stairs. Must be within 3/8 inch of other treads at 12" walk line.
BLD07-00736 BLD-Conference5/16/20075/16/20075/16/2007 9:50:17 AMAPASS
ok to insul. Needs to complete airseal package.
BLD06-00922 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 9:10:25 AMAPASS
Kenny; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD07-00736 BLD-Framing/Rough-in5/15/20075/16/20075/16/2007 7:52:09 AMACANC
joel; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. canc by contractor via phone.