MEC18-01935
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 4:08:42 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by MICHAEL BYERS- gas piping final ok
|
MEC18-02162
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 3:30:02 PM | P | PASS |
|
|
late afternoon-tanner Phone #: ###-####- A/C coil co ok
|
MEC17-05163
| Final | 5/15/2018 | 5/16/2018 | 5/16/2018 3:01:18 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- per phone call with Dan- will reschedule- surround on outside fireplace needs to be non combustible material per manu install manual outdoor side
|
MEC18-00644
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 2:18:50 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- protection post not installed
|
MEC18-01139
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 2:04:56 PM | P | PASS |
|
|
final ok
|
MEC18-01140
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 1:50:05 PM | P | FAIL |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need drip leg on gas line between shutoff valve and appliance- need to seal lineset penetration outside at A/C location
|
MEC18-02125
| Rough-in | 5/16/2018 | 5/16/2018 | 5/16/2018 1:28:00 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite for inspection
|
MEC18-02125
| Pressure Test | 5/16/2018 | 5/16/2018 | 5/16/2018 1:27:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
|
MEC18-02123
| Rough-in | 5/16/2018 | 5/16/2018 | 5/16/2018 1:01:38 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need access to fireplace- sheetrock stacked in front of it no access for inspection to fireplace or gas entry
|
MEC18-02122
| Rough-in | 5/16/2018 | 5/16/2018 | 5/16/2018 1:00:38 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite for inspection- need all insulation remove to do inspection- left do not cover sticker front window
|
MEC18-02122
| Pressure Test | 5/16/2018 | 5/16/2018 | 5/16/2018 12:59:33 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
|
MEC18-02124
| Rough-in | 5/15/2018 | 5/16/2018 | 5/16/2018 10:51:45 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite- need to fix all rips and tears in arma flex- gas piping needs to be secured to support in garage- b vent needs 1" clearance to combustibles at roof on water heater flue
|
MEC18-02124
| Pressure Test | 5/15/2018 | 5/16/2018 | 5/16/2018 10:49:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
|
MEC18-02151
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 10:19:21 AM | A | PASS |
|
|
ac coil co ok
|
MEC18-00698
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 9:31:44 AM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- inspection done in AM
|
MEC18-00698
| Final | 5/16/2018 | 5/16/2018 | 5/16/2018 9:31:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown- final ok
|
MEC18-00644
| Final | 5/15/2018 | 5/16/2018 | 5/16/2018 9:09:45 AM | A | FAIL |
|
|
if you could call Skip when you arrive that would be great. Phone #: ###-#### Inspection requested via web by Devony Bullard- need protection post installed at furnace and water heater location- everything else ok
|
MEC18-02142
| Rough-in | 5/14/2018 | 5/16/2018 | 5/16/2018 9:05:46 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- gas line needs inserted into appliance
|
MEC18-01010
| Final | 5/15/2018 | 5/16/2018 | 5/16/2018 8:49:13 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace final ok
|
MEC17-04060
| Mec-Aging Inspection | 5/16/2018 | 5/16/2018 | 5/16/2018 8:09:28 AM | | PEND |
|
|
contractor will schedule final per phone call
|
MEC15-02333
| Mec-Aging Inspection | 5/16/2018 | 5/16/2018 | 5/16/2018 8:02:38 AM | | FAIL |
|
|
building permit needs issued still under review
|