Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-03157 ELE-Aging Inspection5/17/20165/17/20165/20/2016 3:28:10 PM CANC
ELE16-01431 Final5/17/20165/17/20165/17/2016 3:05:39 PMPPASS
Call half hour before // Joe Phone #: ###-#### Final ok
ELE16-01569 Permanent Service5/17/20165/17/20165/17/2016 2:36:56 PMPPASS
Call before you come I''m doing a service change Phone #: ###-#### Inspection requested via web by Neal Rumsey
Moving dryer, water heater circuit 12 ga shall fuse down or change.
p/s o/h rec ok
ELE15-03901 Electrical Rough-In5/17/20165/17/20165/17/2016 1:43:44 PMPPASS
R/I of walls on 6th floor in NW corner of building, call Joey for inspection. Phone #: ###-#### Inspection requested via web by Rafael Castillo
Noted on contractor print and in book in blue. wall rough in ok cover
ELE16-01512 Electrical Rough-In5/16/20165/17/20165/17/2016 1:29:15 PMAPASS
Asher Sears will be the electrician onsite Phone #: ###-#### Inspection requested via web by steve ragan
Small TI to right of corridor wall rough in ok cover
ELE16-01513 Electrical Rough-In5/16/20165/17/20165/17/2016 12:20:03 PMAPASS
Asher Sears will be the electrician onsite. Phone #: ###-#### Inspection requested via web by steve ragan
Corridor wall rough in ok cover
ELE16-01062 Electrical Rough-In5/17/20165/17/20165/17/2016 11:15:05 AMPCANC
We are requesting a wall rough-in inspection for this afternoon. Our contact is Rich @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
This permit for generator and epuipment related.
ESC16-00246 Random Inspection5/17/20165/17/20165/17/2016 11:14:30 AMPPASS
Landscape sub grade complete. OK
ELE16-01062 Conference5/17/20165/17/20165/17/2016 11:12:56 AMPDONE
We are requesting a wall rough-in inspection for this afternoon. Our contact is Rich @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Do to a change in gear required to complete install area created behind west gear which could entrap someone if fault occured. Contractor to install door on west side of gear and install panic hardware on all doors and all doors shall open out of electrical room new and existing. Other conference notes about generator and gear on permit number ELE15-03984.
ELE16-01491 Electrical Rough-In5/17/20165/17/20165/17/2016 11:11:06 AMPPASS
Wall rough in as noted on contractor print rough in ok cover
ELE16-01553 Electrical Rough-In5/16/20165/17/20165/17/2016 10:02:04 AMAFAIL
Inside walls Phone #: ###-#### Inspection requested via web by Jim Williams
210.64- A receptacle outlet shall be installed on rear of residence to serve as service receptacle for AC unit.
210.70(B)(2)- At least 1 outlet controlled by wall switch shall be install at outdoor entrances.
250.20- AC systems shall remain grounded. Install grounding electrode system to old service to provide ground until service change done.
ELE15-03682 Electrical Rough-In5/16/20165/17/20165/17/2016 9:47:31 AMACANC
Please call 30min prior for access - Warren Phone #: ###-####
Upstairs rough in ok cover
ELE16-00957 Final5/17/20165/17/20165/17/2016 8:32:01 AMAPASS
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok