Inspections for the day of: Thursday, May 17, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00257 ELE-Aging Inspection5/17/20185/17/20185/21/2018 3:06:53 PM PASS
final scheduled
ELE17-03710 Final5/17/20185/17/20185/17/2018 2:17:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
ELE18-01475 Final5/17/20185/17/20185/17/2018 1:50:19 PMPPASS
Door code is 2677 Phone #: ###-#### Inspection requested via web by Ron Zimmerman...ok to final
ELE18-01475 Electrical Rough-In5/17/20185/17/20185/17/2018 1:49:06 PMPPASS
Door code is 2677 Phone #: ###-#### Inspection requested via web by Ron Zimmerman...ceiling grid ok to cover
ELE18-01224 Final5/17/20185/17/20185/17/2018 12:01:34 PMPPASS
Pls contact Mike (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes..
labelling, OCPD, and disconnect ok...40A breaker in panel
ELE18-01224 Electrical Rough-In5/16/20185/17/20185/17/2018 12:00:06 PMAPASS
Pls contact Mike (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes...UL listed equipment verified
ELE18-01546 Final5/16/20185/17/20185/17/2018 11:39:48 AMAPASS
Remodel....people will be around so no garage code needed. Call Heath at ###-#### with any quesstions Phone #: ###-#### Inspection requested via web by Heath Thomas..ok to final
ELE18-00408 Electrical Rough-In5/16/20185/17/20185/17/2018 11:16:19 AMAPASS
We need a ceiling inspection. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker...open junction boxes from previous inspection verified made up from access in hallway...grid cover ok on listed rooms with contractor
ELE18-01813 Final5/17/20185/17/20185/17/2018 10:25:27 AMAPASS
Please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz...panel labelling and grounding ok to final
ELE18-01813 Permanent Service5/16/20185/17/20185/17/2018 10:24:39 AMAPASS
Please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz....replaced burnt split bus panel
ELE18-01826 Electrical Rough-In5/16/20185/17/20185/17/2018 10:04:56 AMAPASS
Please Call Me for Entry Code! Thx. Steve, ###-#### Phone #: ###-#### Inspection requested via web by Steven Meredith...kitchen remodel...junction box accessible in basement ceiling...rough ok to cover
ELE18-01709 Electrical Rough-In5/17/20185/17/20185/17/2018 9:47:22 AMAPASS
Cover up inspection any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller...feeds to back NE corner ok to cover..feeder from shop unable to verify-already covered-electrical contractor will take full resposibillity of all baried pipes
ELE18-01384 Final5/16/20185/17/20185/17/2018 9:19:03 AMAFAIL
Homeowner will be home. Please give them a call to let them know you are headed there Rick ###-####. If you have any questions please feel free to contact Justin ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...all outlets in garage shall be GFI protected...3 east wall outlets by panel
ELE18-01850 Permanent Service5/17/20185/17/20185/17/2018 9:00:37 AMAFAIL
re energize existing service Phone #: ###-#### Inspection requested via web by Nick Larson...service grounding shall be brought up to 2008 code...additional ground rod is needed, verify water line is bonded within 5' of enterance into house, and verify hot/cold waterlines bonded together
ELE18-00327 Final5/16/20185/17/20185/17/2018 8:41:36 AMAPASS
CALL JEFF TO GET ACCESS ###-#### Phone #: ###-#### Inspection requested via web by A.M.E. Office...ok to final
ELE18-00327 Electrical Rough-In5/17/20185/17/20185/17/2018 8:40:55 AMPPASS
CALL JEFF TO GET ACCESS ###-#### Phone #: ###-#### Inspection requested via web by A.M.E. Office...ceiling grid ok to cover hall and 3 offices