ELE07-01817
| Rough-In Permanent Service | 5/18/2007 | 5/18/2007 | 5/18/2007 4:10:05 PM | P | FAIL |
|
|
dan Note: water pump; Note:please call dan before inspection Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. stop work poste needs bld permit for retainning wall and pump comp needs ele permit for their work nec 110.26(F)(2) move p/s or remove retainning wall clearence for p/s alos grd rods shall be driven flush
|
ELE07-01819
| Electrical Rough-In | 5/18/2007 | 5/18/2007 | 5/18/2007 2:08:41 PM | P | PASS |
|
|
glen; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok survey posted for outlets required 3 locations right of new door din rm, right of door new siiting rm by kit din rm, between old and new door M bed rm called
|
ELE05-02692
| Final | 5/18/2007 | 5/18/2007 | 5/18/2007 1:26:43 PM | P | FAIL |
|
|
jay - pls call jerri haack at ###-#### 15 min prior to meet you; Internet Inspection Request from: Cathy Chiles called left message at 1:00 pm no response back
|
ELE05-02936
| Final | 5/18/2007 | 5/18/2007 | 5/18/2007 1:02:51 PM | P | FAIL |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Darla Downs needs light for panel in basement, and required outlets for new peninsular counter in kit,dinning room
|
ELE07-01024
| Final | 5/18/2007 | 5/18/2007 | 5/18/2007 12:06:52 PM | P | PASS |
|
|
stu - for easy money suite 101; Phone #: ###-#### Internet Inspection Request from: Delphine Kavanaugh ok card signed
|
ELE07-01813
| Electrical Rough-In | 5/17/2007 | 5/18/2007 | 5/18/2007 11:57:27 AM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham studio ok
|
ELE07-00763
| Final | 5/17/2007 | 5/18/2007 | 5/18/2007 10:58:58 AM | A | PASS |
|
|
On site Journeyman - Gene ###-####. Thanks!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok card signed
|
ELE06-00711
| Electrical Rough-In | 5/17/2007 | 5/18/2007 | 5/18/2007 10:15:46 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 5/17/2007 at 8:30:50 AM. Contact: ###-####. talked with Todd high entry ceiling ok for tiles
|
ELE07-01782
| Permanent Service | 5/17/2007 | 5/18/2007 | 5/18/2007 9:58:25 AM | A | FAIL |
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Victoria Beall paitial corr only 110.26(F)(2) remove everything foreign to elect from below panel gas pipe ,etc. 240.24(A) panel set too high, 250.104(A)(1) bond water system, install 2 grd rods, needs conn for GEC, 408.4 specific panel schedule, address wiring to range and dryer? called owner note Idaho power hooked p/s up on the weekend with no inspection frist
|
ELE07-01810
| Rough-In Permanent Service | 5/17/2007 | 5/18/2007 | 5/18/2007 9:18:56 AM | A | PASS |
|
|
Raj Phone #:###-####, please call for access Internet Inspection Request from: Cathy Chiles r/i p/s u/g new ok
|
ELE07-01808
| Electrical Rough-In | 5/17/2007 | 5/18/2007 | 5/18/2007 8:38:57 AM | A | PART |
|
|
jERRY NOTE: BONDING FOR POOL; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles pool bond only no E grdi
|