Inspections for the day of: Friday, May 18, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01811 Final5/17/20075/18/20075/18/2007 4:10:36 PMPCANC
justin- ###-#### - call 1st before insp not done, see rip
ELE07-01811 Rough-In Permanent Service5/17/20075/18/20075/18/2007 4:09:45 PMPPASS
justin- ###-#### - call 1st before insp met contr left corr notice, told to call for Monday am inspection to correct following: nec 312.5 abrasion protection shall be provided for all conductors entering enclosures, 250.33 shall install 2 ground rods, 250.52(A) shall ground water pipe entering house, 110.3(A) shall use listed clamps, 230.24 shall provide 8' clearance over roof surface, 240.24(D)(E) shall not have overcurrent devices in closet,BCC shall install 2" mast, NOTE: this may not be final correction bnotice, reserve right to disconnect power if corrections not made. p/s o/h rec ok
ELE07-01499 Electrical Rough-In5/17/20075/18/20075/18/2007 2:11:28 PMPCANC
erin ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall wrong type inspection, see rip
ELE07-01499 Rough-In Permanent Service5/18/20075/18/20075/18/2007 2:10:55 PMPPASS
erin ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok p/s o/h rec ok, told owner to use crimper for gnd tails, move closet shelf
ELE07-00147 Electrical Rough-In5/18/20075/18/20075/18/2007 1:45:10 PMPPART
lorin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover ceilings back 1/2
ELE07-01799 Permanent Service5/18/20075/18/20075/18/2007 12:57:16 PMPPASS
jason; Phone #: ###-#### Internet Inspection Request from: Delphine Kavanaugh p/s o/h rec ok
ELE07-01632 Electrical Rough-In5/17/20075/18/20075/18/2007 12:39:35 PMPPASS
CALVIN; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric inside house ok
ELE07-00047 Final5/18/20075/18/20075/18/2007 11:44:47 AMAPASS
ok to final, starting more work under new permit
ELE07-01147 Electrical Rough-In5/18/20075/18/20075/18/2007 11:43:32 AMAPART
Scheduled by a contractor via Hello! on 5/18/2007 at 7:02:04 AM. Contact: ###-####. ric walls only ok
ELE07-01145 Electrical Rough-In5/18/20075/18/20075/18/2007 11:07:46 AMAPART
Scheduled by a contractor via Hello! on 5/18/2007 at 7:00:38 AM. Contact: ###-####. walls only ok to cover
ELE06-02158 Final5/17/20075/18/20075/18/2007 10:49:08 AMAPASS
office -- would like as early as possible; Phone #: ###-#### Internet Inspection Request from: Darla Downs called contr about some outlets not working, gfci wont reset, owner will call, ok to final
ELE07-01744 Final5/17/20075/18/20075/18/2007 9:21:47 AMANR
Please call James at ###-#### if any problems. Thanks, Andrea. Phone #: ###-#### x0000 Internet Inspection Request from: Andrea Creek panel ok, need to see panel schedule for final (inside house), screw jb closed, need to finish make-up in inside panel, called and said to call for final, check panel covers installed in house and garage
ELE07-01217 Electrical Rough-In5/17/20075/18/20075/18/2007 8:51:55 AMAPASS
bruce; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to cover ceiling
ELE07-01814 Rough-In Permanent Service5/17/20075/18/20075/18/2007 8:23:51 AMAPASS
core and shell with house panel and house panel wiring inside for cover thank you Brad Phone #: ###-#### Internet Inspection Request from: Brad Baker called contr, about survey for too many 90"s in flex, nailplates couple places, ric ok, p/s u/g n ok 1 meter only