Inspections for the day of: Thursday, May 18, 2017.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-01757 BLD-Framing/Rough-in5/18/20175/18/20175/18/2017 4:16:29 PMPPEND
Steve Phone #: ###-####. Roof nailing on bldg. 200. Used staples, plans call for 8d nails. Waiting for RFI from engineer.
BLD17-01244 BLD-Final5/17/20175/18/20175/18/2017 3:48:15 PMPNR
Hakizimana Phone #: ###-####-please call 30 minutes prior for access
BLD17-00277 BLD-Final5/18/20175/18/20175/18/2017 3:10:07 PMPCANC
Clinton Phone #: ###-####
BLD14-01769 BLD - Request for Extension5/18/20175/18/20175/18/2017 2:06:08 PMPPEND
Ted Mason Phone #: ###-####. Called and left message for Ted. Noted that he needs to send a letter to B.O. for extension request.
BLD17-00915 BLD-Final5/17/20175/18/20175/18/2017 1:33:43 PMPPASS
Any time after 1:00 pm will work best. Phone #: ###-#### Inspection requested via web by Brent Anderson
BLD17-00915 DOC - Permit Finaled5/18/20175/18/20175/18/2017 1:33:34 PMPPASS
BLD14-02652 BLD-Final5/18/20175/18/20175/18/2017 1:12:48 PMPDONE
Mark Phone #: ###-#### Inspection requested via web by mark cada
BLD14-02652 DOC - Permit Finaled5/18/20175/18/20175/18/2017 1:12:39 PMPPASS
All work appeared to be done in acoordance with local codes and ordinances.
BLD17-00746 BLD-Footing5/17/20175/18/20175/18/2017 10:42:09 AMANR
Please call ahead for access - Chris Phone #: ###-####. Will reschedule.
BLD17-00409 BLD-Final5/17/20175/18/20175/18/2017 10:09:26 AMAFAIL
Lexie Phone #: ###-####. Provide landings at bottom of stairs. Back stairs not code compliant, riser height exceeds the 7.75 inch max riser height. Front stairs, handrail to low.
BLD17-00238 BLD-Final5/17/20175/18/20175/18/2017 9:34:35 AMAPASS
Please call ahead for access - Joe Phone #: ###-####
BLD17-00238 DOC - Permit Finaled5/18/20175/18/20175/18/2017 9:34:26 AMPPASS
BLD16-04313 BLD-Footing5/17/20175/18/20175/18/2017 9:34:15 AMAFAIL
Marty-pour 9:00 Phone #: ###-####. Remove mud from rebar, plans call for 18 inch wide footing, verts not tied in place.
ESC17-00507 Site Preparation5/18/20175/18/20175/18/2017 9:00:32 AMAPART
Needs to post ESC permit sign. Spoke to RP. He noted that he has been posting signs when at framing stage. RP noted that new signs are not durable and only last a week when posted.
BLD17-01208 BLD-Footing5/17/20175/18/20175/18/2017 8:59:10 AMAPASS
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo Lira
BLD17-00781 BLD-Framing/Rough-in5/18/20175/18/20175/18/2017 8:42:29 AMAFAIL
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Nail off king studs to header at door from garage to house. Provide truss engineering. Strap double top plate splice at racked wall at peak on both sides. Provide additional stud at double top plate splice at peak on north wall. Nails over driven on hangars on A17 truss. Replace with new hangars. Correction notice posted. ok to insulate.