Inspections for the day of: Monday, May 19, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-01296 Electrical Rough-In5/19/20085/19/20085/19/2008 3:57:52 PMPPASS
UFFER GROUND INSPECTION Phone #: ###-#### Internet Inspection Request from: JENNY EMEL called contractor, concrete encased electrode ok to pour
ESC08-00296 General Inspection5/19/20085/19/20085/19/2008 3:17:18 PMAPASS
looked ok
ELE08-01274 Rough-In Permanent Service5/19/20085/19/20085/19/2008 3:01:29 PMPPASS
Scheduled by a contractor via Hello! on 5/19/2008 at 8:20:27 AM. Contact: ###-####. corrections made ric ok, p/s u/g rec ok
ELE08-01278 Rough-In Permanent Service5/19/20085/19/20085/19/2008 2:20:13 PMPPASS
ready for re-inspection. Phone #: ###-#### Internet Inspection Request from: Lynn Cable corrections made, ric ok, p/s u/g n ok
ELE08-00845 Final5/13/20085/19/20085/19/2008 1:22:13 PMPPASS
questions on electrical call Corey ###-####
homeowner ####-#### CALL BEFORE YOU GO Internet Inspection Request from: Yolanda Morris corrections made, ok to final
ELE08-01063 Electrical Rough-In5/19/20085/19/20085/19/2008 12:41:15 PMPPASS
light capsulation & potential plane inspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers equipotential plane and potting only ok
ELE08-00631 Final5/19/20085/19/20085/19/2008 10:18:58 AMAPASS
Dave will be on job site Phone #: ###-#### Internet Inspection Request from: David Seilheimer ok to final
ELE08-01254 Final5/15/20085/19/20085/19/2008 10:01:00 AMAPASS
GFI Plug Phone #: ###-#### Internet Inspection Request from: Yolanda Morris ok to final
ELE08-01254 Electrical Rough-In5/19/20085/19/20085/19/2008 9:14:54 AMAPASS
GFI Plug Phone #: ###-#### Internet Inspection Request from: Yolanda Morris ric ok
ELE08-01117 Electrical Rough-In5/16/20085/19/20085/19/2008 9:08:33 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Shawn Kelley called, left correction notice, nec 210.52(A)(1)&(2) receptacles shall be within 6' of wall space and walls over 2' shall have receptacle installed-see kitchen wall and room east of kitchen, 210.52(E) shall install receptacle at front of dwelling, 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member Note: minimum 13 rooms for room count
ELE08-01291 Final5/17/20085/19/20085/19/2008 8:18:02 AMAPASS
Knock if no one home key is under mat at rear of home Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok to final
ELE08-01291 Electrical Rough-In5/19/20085/19/20085/19/2008 8:15:58 AMAPASS
Knock if no one home key is under mat at rear of home Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ric ok
ELE08-01175 Final5/16/20085/19/20085/19/2008 8:00:40 AMAPASS
Can be AM or PM at your convenience. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ok to final
ELE08-01175 Electrical Rough-In5/19/20085/19/20085/19/2008 8:00:24 AMAPASS
Can be AM or PM at your convenience. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ric ok